Basic Accuracy: Experience unparalleled precision with a basic accuracy of ±0.04%, reaching a remarkable maximum of ±0.025%, ensuring reliability and consistency in all measurements.
Range Ratio: Boasting an impressive range ratio of 100:1, this transmitter is designed to accommodate a wide spectrum of pressure differentials with exceptional versatility.
Response Time: Swift and efficient, the response time of just 90ms with a data refresh rate of 50ms ensures real-time accuracy and efficiency.
Range Range: The transmitter covers a vast differential pressure range from 0-100 Pa to 14MPa, catering to diverse processing needs.
Pressure Range: Efficiently handles a pressure spectrum from 0-1 kPa to a staggering 70MPa, showcasing its adaptability to various operational environments.
Output Signal: Equipped with a 4-20 mA output signal enhanced by HART protocol communication, compatible with HART 6.0 and HART 7.0 versions for seamless integration.
PROFIBUS-PA Communication: Includes PROFIBUS-PA fieldbus communication, version 3.02, for advanced connectivity and integration.
FF Fieldbus Communication: Features FF Fidbus Communication Version 6.1.1, ensuring robust and reliable field-level networking.
Overload Limit: Capable of withstanding an overload limit of 42MPa for differential pressure, safeguarding against extreme conditions.
Pressure Overload: Withstands up to 105MPa, reflecting its resilience and durability under intense pressure scenarios.
Static Pressure Effect: Impressively manages static pressure effects at 0.03%FS / 16MPa, maintaining accuracy under varying conditions.
Temperature Range: Operates efficiently in ambient temperatures from -40ºC to 80ºC. For explosion-proof applications, please refer to the designated explosion-proof grade.
Process Temperature: Designed to handle extreme process temperatures ranging from -90ºC to a blistering 700ºC, catering to comprehensive operational demands.
LCD Temperature: The LCD functions seamlessly within a temperature range of -35ºC to 80ºC, ensuring clear visibility and performance.
Long-term Drift: Guarantees minimal drift with a low ± 0.1%FS over 10 years, promising sustained precision and reliability over time.
Temperature Effect: Maintains accuracy with a temperature effect of (0.06 * r + 0.01)% per 28ºC within the -40ºC to 80ºC range.
Explosion-proof Grade: NEPSI certified, Type Ex iaIICT4 Ga, suitable for ambient temperatures from -40ºC to 60ºC, ensuring safety in explosive environments.
NEPSI Intrinsic Safety: Certified as Ex iaIICT6 Ga, applicable from -40ºC to 40ºC, offering intrinsic safety for sensitive operations.
NEPSI Explosive Type: Classified as Ex dIICT6 Gb for ambient conditions -40ºC to 60ºC, providing robust protection against explosive risks.
NEPSI Dust Explosion: Rated Ex tD A21 IP67 T85ºC, this ensures reliable dust explosion protection.
NEPSI 'n' Explosion-proof: Rated Ex nACT6 Gc for -40ºC to +60ºC, delivering dependable protection in potentially explosive atmospheres.
ATEX Certification: Rated Ben Ex II 1 G Ex iaIICT4 Ga, demonstrating superior safety under explosive conditions.
ATEX Burst: Rated Ex II 1 / 2 G Ex dbIICT6-T 4 Ga / Gb, built to withstand explosive scenarios with utmost safety.
IECEx Intrinsic Safety: Rated Ex iaIICT4 Ga, offering intrinsic safety as per IECEx standards.
IECEx Burst: Rated Ex dbIICT6-T 4 Ga / Gb, providing robust protection in explosive conditions, adhering to international standards.