Basic Accuracy: Experience unparalleled precision with an outstanding basic accuracy of ±0.04%, reaching a maximum accuracy of ±0.025% for the most meticulous industrial applications.
Range Ratio: Achieve versatility with an impressive range ratio of 100:1, offering flexibility across diverse measurement needs.
Response Time: Benefit from a swift response time of 90ms, with a rapid data refresh rate of 50ms, ensuring real-time accuracy and efficiency.
Range Range: Seamlessly measure differential pressures from 0-100 Pa up to an expansive 14MPa, enhancing your operational capabilities.
Pressure Range: Withstand and measure pressures from 0-1 kPa stretching to a robust 70MPa, catering to high-demand environments.
Output Signal: Utilize a reliable 4-20 mA signal overlaid with HART protocol communication, compatible with versions HART6.0 and HART 7.0 for seamless integration.
PROFIBUS-PA Fieldbus Communication: Leverage version 3.02 for efficient and effective data transmission, enhancing connectivity and control.
FF Fieldbus Communication: Version 6.1.1 provides sophisticated communication capabilities for intricate industrial systems.
Overload Limit: Robust design supports a differential pressure overload capacity of up to 42MPa, ensuring durability and reliability.
Pressure Overload: Safely manage pressures up to an impressive 105MPa, designed for rigorous industrial applications.
Effect of Static Pressure: Minimal influence, only 0.03%FS at 16MPa, guaranteeing stable and consistent readings.
Temperature Range: Operate confidently within ambient temperatures of -40ºC to 80ºC. For explosion-proof conditions, refer to the specified grade details.
Process Temperature: Adaptable to process temperatures ranging from -90ºC to a high of 700ºC, suitable for extreme conditions.
LCD Temperature: Ensures display reliability within a range of -35ºC to 80ºC, maintaining clarity and visibility.
Long-term Drift: Expect negligible drift, with a long-term stability of ±0.1%FS over a decade, maintaining precision over time.
Temperature Effect: Extremely low thermal impact at (0.06 * r + 0.01)% over 28ºC, within a range of -40ºC to 80ºC.
Explosion-Proof Grade: Certified under NEPSI as Type Ex iaIICT4 Ga, suitable for ambient temperatures from -40ºC to 60ºC, ensuring safety and compliance.
NEPSI Certification: Intrinsically safe Ex iaIICT6 Ga for ambient temperatures from -40ºC to 40ºC, providing robust safety assurances.
Explosion Type NEPSI: Certified Ex dIICT6 Gb for ambient temperatures -40ºC to 60ºC, for environments requiring stringent safety measures.
Dust Explosion NEPSI: Ex tD A21 IP67 T85ºC certified, designed for environments with dust explosion risks.
NEPSI 'n' Explosion-Proof: Ex nACT6 Gc certified, operational in ambient temperatures from -40ºC to +60ºC, offering peace of mind.
ATEX Certification: Ben Ex II 1 G Ex iaIICT4 Ga approval, ensuring high safety standards for hazardous areas.
ATEX Burst Proof: Ex II 1 / 2 G Ex dbIICT6-T 4 Ga / Gb certified, providing exceptional protection in explosive atmospheres.
IECEx Intrinsic Safety: Approved as Ex iaIICT4 Ga, designed for intrinsically safe applications, adhering to global standards.
IECEx Burst Proof: Certified as Ex dbIICT6-T 4 Ga / Gb, ensuring high-level safety for burst-prone environments.