Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

Product Details
Customization: Available
Accuracy: 0.15%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (10)
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
  • Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Size
DN6-80
Sensor
Tube/Flange
Application
Environmental Protection
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measurement Object
Closed Pipeline
Certification
CE
Process Temperature
-100~180°c
Ambient Temperature
-40~60°c
Range
0.67~885nm3/H
Flange Standard
ANSI
Flange Material
316L
Flange Size
ANSI 2"150RF
Body Material
Aluminum
Element Material
316L
Mounting Style
Integral
Power Supper
24VDC
Output Signal
4-20mA
Output Indicator
Yes
Electrica Connect
1/2"NPT
Explosion Proof
Ex Ia Iict4
Pressure
0-50bar
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
100000peices/Years

Product Description

N Series Normalized Mass Flow & Density Meter
. Applied to Liquid Mass Flow

. Mass Flow Accuracy
. Density Measuring Accuracy . Normal Diameter
. Process Temperature Ranges
±0. 15% / ±0.2%
±2kg/m3
DN4~DN250 -40ºC~+350ºC

Component Parts of N Series Coriolis Mass Flow Meter
N Series Coriolis Mass Flow Meter is defined as N series Mass Flow Meter with flow accuracy is 0. 15% or 0.2%, whom is made of N series mass flow Sensor and DPT100 Transmitter.

Features and Benefits of N Series Coriolis Mass Flow Meter
l Double U or double C type flow pipe design is better for measuring accuracy
l Provides integrated mass flow, volume flow, density, temperature measurement and the computes other essential parametersmetrics
l Effortless in setup, no requirement for rectifiers, filter components, no specific conditions for installation straight pipeline segment
l Without moving components and no requirement for regular upkeep; superior consistent operationalperformance no need for frequent adjustments
l Facilitates low-range flow operations, minimizing pressure loss, thereby maintaining high efficiency
l Streamlined installation to reduce installation expenses
l Seamlessly compatible with P series A (flanges surfaces interval dimensions)
l The integrated Transmitter can be swapped for hassle-free maintenance
l Unaffected by ambient temperatures
Liquid Flow Rate Performance Metrics

 

Maximum mass flow rate
N5
N10  
N15  
N20   
N25   
N50  
N80   
N100 
N150 
N200 
N250
Mass flow rate Kg/h

500
1500
4500
9450
25500
94500
240000
540000
825000
1650000
2700000
Volume flow rate[1] L/h

500
1500
4500
9450
25500
94500
240000
540000
825000
1650000
2700000
Mass flow accuracy[2]       15:1 within turndown[3] ±0. 15%
15:1 beyond turndown ±(zero stability/instant rate)×100%


Volume flow precision[2] Full Scale ±0. 15±(Zero Stability / Immediate Flow Rate) × 100%
_______________________________________________________________
Repeatability 15:1 within turndown ±0.075%
  15:1 beyond turndown ±1/2(Zero Stability / Instant Flow Rate)×100%
    Kg/h
Zero Stability N5
N10   
N15   
N20   
N25   
N50   
N80   
N100 
N150 
N200 
N250

0.05
0.15
0.45
0.95
2.55
9.45
24.00   54.00   82.50   165.00 270.00

[1]The standard for volume flow rate is in accordance with density. Regarding to the process liquid density isn't 1000kg/m3, the value of volume flow is value of maximum mass flow divided by liquid density.
[2]Flow Accuracy includes repeatability, linearity and hysteresis.
[3]Turndown is defined as the value of maximum flow divided by minimum flow.

Density Performance Index(only liquid)
 
Accuracy[1] ±0.002g/cm3 ±2.0kg/m3
Repeatability ±0.001g/cm3 ±1.0kg/m3
Measuring Range 0.2~3.00g/cm3 200~3000kg/m3

Structure Material
Wetted Parts Sensitive Pipe
Separated Liquid Flange
00Cr17Ni14Mo2(316L)
0Cr18Ni9(304)or 00Cr17Ni14Mo2(316L) 0Cr18Ni9(304)or 00Cr17Ni14Mo2(316L)
Cover Sensor
Transmitter
Junction Box
0Cr18Ni9(304)
Cast aluminum alloy(coated polyester epoxy) Cast aluminum alloy(coated polyester epoxy)





 
Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

Features and Benefits of N Series Coriolis Mass Flow Meter
l Double U or double C type flow pipe design is better for measuring accuracy
l Provides integrated mass flow, volume flow, density, temperature measurement and the calculates the others relevant parameters
l Easy on installation, no need rectifier, filter parts, no special requirements for installing direct pipe section
l This advanced device operates seamlessly without moving parts, eliminating the need for frequent maintenance. It offers a high degree of stability and functionality, requiring no frequentcalibration. This meter ensures no need for constant calibration.
l It allows for low-range flow operation, minimizing pressure loss to maintain highefficiency and productivity. efficiency.
l The compact design facilitates installation, significantly reducing installation costs.
l This product is fully compatible with P series A (with flange face intervals and distance) dimensions.
l The connected Transmitter is easilyexchangeable for effortless
maintenance. Reliably unaffected by changes in ambienttemperature conditions.


N200 Remote Installation offers enhanced flexibility.Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

Note: The flanges listed in the tables below are welding-neck steel pipe flanges with RF connections.


Flange(GB/T 9115-2010)


A


B


C


E


F


H


M


I

D

n
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
200(Standard) 4.0 1206 1005 1407 380 290 287 30 320 375 12
250(Optional) 4.0 1240 1005 1407 380 290 287 33 385 450 12
Flange(HG/T 20615-2009)
A

B

C

E

F

H

M

I

D

n
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
200(Optional) 300 1252 1005 1407 380 290 287 26 330.2 380 12
250(Optional) 300 1264 1005 1407 380 290 287 30 387.4 445 16


 

Company Profile
Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a distinguished pillar within the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., epitomizing a steadfast commitment to unparalleled innovation and excellence.
(hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) officially embarked on its innovative journey in the vibrant cityscape of Shanghai in 2013, heralding a transformative era of technological progress.
The founding team, composed of industry veterans from the world's foremost automation leaders, brings an extraordinary wealth of experience: over 20 years in the automation sector, in addition to two decades in automation engineering, and 10 years in pioneering digital solutions. Their mission is unequivocal: to deliver premier automation and digitization products and services to clients worldwide. Rooted strategically in Shanghai, China, the company is a shining icon of technological expertise.
Boasting an impressive legacy exceeding two decades in the petrochemical realm, the company holds unmatched insights into the automation and digitalization needs across the entire industry spectrum-upstream, midstream, and downstream. They offer a suite of professional-grade products and comprehensive solutions, meticulously crafted for industries such as petroleum, chemical, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, guaranteeing excellence throughout the product lifecycle.
Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments
Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh EnvironmentsReliable Coriolis Mass Flow Meter Density Transmitter for Harsh EnvironmentsReliable Coriolis Mass Flow Meter Density Transmitter for Harsh EnvironmentsReliable Coriolis Mass Flow Meter Density Transmitter for Harsh EnvironmentsReliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

Reliable Coriolis Mass Flow Meter Density Transmitter for Harsh EnvironmentsReliable Coriolis Mass Flow Meter Density Transmitter for Harsh Environments

You may have these questions

How do I select the right product?
A: Upon receiving your inquiry, our extensive technical dossier will furnish all the essential insights you require. This documentation empowers you to thoroughly examine the process parameters and technical specifications pertinent to your needs. Armed with this information, we will expertly recommend the model that aligns impeccably with your precise requirements.

I would like a confirmed model. Can you provide that?
A: Absolutely. Once you express interest in a particular model, we will undertake a meticulous verification process to ensure its suitability. Should there be opportunities for cost-effective enhancements, we will readily propose optimization suggestions. Upon your confirmation, we will proceed to craft a formal quotation, meticulously tailored to meet your objectives.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier