Customization: | Available |
---|---|
Opere Temperature: | -40~85°c |
Range: | ±80g |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Transducer | Amplitude | Maximum Analysis Frequency | Sampling Rate |
Vibration Total X | Max 16g's | Max 1,000Hz | 2.6kHz |
Vibration Total Y | Max 16g's | Max 1,000Hz | 2.6kHz |
Vibration Total Z | Max 80g's | Max 20,000Hz(3) | 51.2kHz |
PeakVueZ | Max 80g's | Max 5,000Hz | 51.2kHz |
Temperature | -40°C to 85°C |
Working Conditions | ||
Operating Temperature Range | -40 to 85°C | |
Operating Humidity | 95%,Non-Condensing |
Advanced Diagnostics | ||
Analysis Parameters | 2 velocity bands (default: 2-65Hz and 65-300Hz) | |
2 acceleration bands (default: 10-500Hz and 500-1000Hz) | ||
Prescriptive Analysis | Bearing/Mechanical Severity | |
Lubrication Fault Severity | ||
Machine Speed (RPM) Calculation(4) | ||
Vibration Waveform and Spectrum | Main Shaft (Z): | |
User Selectable FMax(2): 100Hz, 200Hz; 500Hz; 1kHz(5); 2kHz; 5kHz, 10kHz, 20kHz | ||
User Selectable FMin(2): 2Hz(5), 10Hz | ||
User Selectable Resolution(2): 100, 200, 400, 800, 1600(5) lines | ||
Secondary Shaft (X, Y)(1): | ||
User Selectable FMax: 200, 500 and 1000(5)Hz | ||
User Selectable Lines or Resolution: 100, 200, 400(5), 800, 1600 lines | ||
Diagnostic Compressed Maps | Based on 1600 lines resolution for speed and PeakVue |
Wireless Protocol | ||
Protocol | IEC62591WirelessHART® | |
Transmission Range | Up to 100 meters line-of-sight | |
Radio Frequency Band | 2405-2480MHz | |
Nominal Output Power | 8dBm or 0.0063W | |
Hazardous Location Certification | ||
USA/Canada | ClassI,Div1GrpsA-D | ClassII,Div1GrpsE,F,G(Pending) |
ATEX | Zone0,ExiaIICT4 | ATEXDirective(94/9/EC) |
IECEx | Zone0,ExiaIICT4 |