Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

Product Details
Customization: Available
Accuracy: 0.15%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (10)
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
  • Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
P50
Size
DN6-80
Sensor
Tube/Flange
Application
Environmental Protection
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measurement Object
Closed Pipeline
Certification
CE
Process Temperature
-100~180°c
Ambient Temperature
-40~60°c
Range
0.67~885nm3/H
Flange Standard
ANSI
Flange Material
316L
Flange Size
ANSI 2"150RF
Body Material
Aluminum
Element Material
316L
Mounting Style
Integral
Power Supper
24VDC
Output Signal
4-20mA
Output Indicator
Yes
Electrica Connect
1/2"NPT
Explosion Proof
Ex Ib LLC T3~T6
Pressure
0-50bar
Transport Package
Wooden
Trademark
Xi′an Dongfeng
Origin
China
HS Code
9026100000
Production Capacity
100000peices/Years

Product Description

P Series Precise Mass Flow & Density Meter
. Expertly engineered for the accurate measurement of Liquid, Gas, and Slurry Mass Flow, ensuring precision in every reading.
. Mass Flow Accuracy ±0. 1%(Liquid),±0.5%(Gas) . Density Measuring Accuracy ±1kg/m3
. Normal Diameter DN10~DN250
. Process Temperature Ranges -40ºCto+350ºC
Component Parts of P Series Encompass: Coriolis Mass Flow Meter
P Series Coriolis Mass Flow Meter is defined as P seriesMass Flow Meter with precision flow accuracy is 0. 1%, crafted with P series mass flow Sensor and DPT100 Transmitter.This ensures unparalleled precision and reliability.

Features and Benefits of P Series Coriolis Mass Flow Meterinclude:
l Innovative Double U or double C type flow pipe design is superior for enhancing measurement
accuracy Provides comprehensive mass flow, volume flow, density, and temperature measurement with unmatched efficiency. and the calculates the others relevant parameters
l Effortless on installation, no need rectifier, filter components, no special requirements for installing direct pipe section
l With no moving parts and no need for frequent maintenance; highly stable functionality no need for frequent calibration
l Allows minimal range flow operation, reducing pressure loss while maintaining high efficiency
l Compact design ensures reduced installation costs
l Fully compatible with N series A(flanges faces interval distance) dimension
l Ultra-precision metering and long-term stability functions for custody transfer measurement
l Ultra-wide turndown ratio for gas measurement
l The Transmitter can be swapped out for simplified maintenancel
l Unaffected by ambient temperature
Liquid Flow Rate Performance Index

 
    Mass flow rate Volume flow rate[1]
    Kg/h L/h
Maximum mass P10 1500 1500
flow rate P15 4500 4500
  P20 9450 9450
  P25 25500 25500
  P50 94500 94500
  P80 240000 240000
  P100 540000 540000
  P150 825000 825000
  P200 1650000 1650000
  P250 2700000 2700000

Mass flow accuracy[2]       15:1 within turndown[3] ±0. 1%
15:1 beyond turndown ±(zero stability/instant rate)×100%


Volume flow accuracy[2] FS ±0. 15±(Zero Stability / Instant Flow Rate) × 100%


 
Repeatability 15:1 within turndown ±0.05%
  15:1 beyond turndown ±1/2(Zero Stability / Instant Flow Rate)×100%

Kg/h
 
Zero Stability

P10 P15 P20 P25 P50 P80 P100 P150 P200 P250

0.10 0.30 0.63 1.70 6.30 16.0 36.0 55.0 110.0 180.0

[1]The criterion of volume flow rate is as per density. Regarding to the process liquid density isn't1000 kg/m3,the value of volume flow is value of maximum mass flow divided by liquid density .This ensures precise volume flow rates for varied liquid compositions.
[2]Flow Accuracy includes repeatability, linearity and hysteresis.
[3]Turndown is defined as the value of maximum flow divided by minimum flow.

Accuracy, Turndown and Pressure Loss of P50 connected with DPT100 Transmitter
Turndown (from the maximum flow) 20:1 15:1 5:1 1.5:1 1:1
Accuracy  ±% 0. 14 0. 1 0. 1 0. 1 0. 1
Pressure Drop MPa 0.001 0.002 0.02 0. 1 0.23

Note:when the maximum flow rate exceeds the given flow rate range,the noise increases substantially. from the pipe will affect the precision and accuracy of the measurements.



Gas Measurement Performance
Mass flow accuracy (flow rate > zero stability/0.005) ±0.5%
(flow rate < zero stability/0.005) ±Precise (zero stability/instant flow rate)x100% Mass flow repeatability (flow rate>zero stability/0.005) ±0.25%
(flow rate<zero stability/0.005) ±1/2(zero stability/instant flow rate)x100%

Standard Volume
In most application areas, customers are accustomed to use standard volume to determine the volume under varying pressure and temperature conditions, where the standard volume is also known as "standard mass" flow unit to the fixed component liquid. Applied to the density under standard condition(receiving from reference data), flow meter would be output under the configuration of standard volume unit, which means that couldd be calculated between measured liquid quality and entrained liquid standard density, but no need the compensation of pressure, temperature, and density. For more information please contact your local agency.


Pressure Loss
Pressure loss is affected by the sensor geometric form, gas density and flow rate. While customers are suggested that the sensor pressure loss couldn't surpass 0. 127MPa when design type selection.


Flow Rate
The flow rate of gas measure is much greater than the flow rate of liquid measure, the higher flow rate leads to the noise will affect the The signal of the flowmeter is crucial. Therefore, the flow rate within the sensor pipe should be lower than 0.5 times that of sound's rate when the pressure loss of the flow meter is under 0. 127Mpa.Ensure
 
Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

Model Selection PrincipleIn
the applied fields of the Coriolis Mass Flow Meter, the maximum flow rate is determined by pressure loss, while the minimum flow rate is dictated by measuring accuracy. Prior to selecting the product, clients or users should
consult this manual, utilizing the size selection software provided by Xi'an Dongfeng Machinery & Electronic Co., Ltd. Furthermore, the user should also rely on the guidance provided by the software. As well as additionalresources offered by the manufacturer. Ensure optimal usage of this state-of-the-art technology. The user should be Provide the relevant data such as accuracy, flow rate, pressure loss, density, viscosity, temperature, etc., which ensures the correct size selection and application. The software can be obtained from salespersons of the agency or downloaded from the company

P50 Compact Installation
Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityNote: The listed flanges in the tables below are welding-neck steel pipe flanges RF
 
Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D

F
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 922 201 18 125 165 180
65(Optional) 4.0 570 460 595 702 922 201 18 145 185 180
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D

F
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 922 201 18 127 165 180
65(Optional) 300 620 460 595 702 922 201 22 149.2 190 180



P50 Remote InstallationTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

Note: The listed flanges in the tables below are welding-neck steel pipe flanges RF

Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 845 201 18 125 165
65(Optional) 4.0 570 460 595 702 845 201 18 145 185
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 845 201 18 127 165
65(Optional) 300 620 460 595 702 845 201 22 149.2 190

 

Company Profile
Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. is a distinguished leader within the prestigious Hanshan (Cold Mountain) Intelligent Technology Co., symbolizing a relentless pursuit of innovation and unparalleled excellence.
(hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) launched its illustrious journey in the bustling metropolis of Shanghai in 2013, marking a groundbreaking chapter in technological advancement.
The founding team comprises industry stalwarts from the globe's leading automation giants, bringing a remarkable arsenal of expertise: over 20 years in automation, two decades in engineering, and a decade in cutting-edge digital solutions. Their mission is clear: to deliver superior automation and digitization products and services globally. Strategically rooted in Shanghai, China, the company stands as a beacon of technological mastery.
With an illustrious history surpassing 20 years in the petrochemical sector, the company wields unparalleled expertise in the automation and digitalization domains across the entire industry spectrum-upstream, midstream, and downstream. They offer a comprehensive suite of professional-grade products and meticulously crafted solutions for industries such as petroleum, chemical, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, ensuring a standard of excellence throughout the product lifecycle.
Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density
Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

Temperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and DensityTemperature-Sensitive Coriolis Flowmeter for Accurate Mass Flow and Density

You may have these questions

How do I select the right product?
A: Upon receiving your inquiry, our extensive technical dossier provides all the essential knowledge you need. This documentation allows you to thoroughly analyze the process parameters and technical specifications relevant to your requirements. Equipped with this information, we will expertly recommend the model that aligns perfectly with your specific needs.

I would like a confirmed model. Can you provide that?
A: Absolutely. Once you express interest in a specific model, we will conduct a thorough verification process to ensure its compatibility. If there are opportunities for cost-effective improvements, we will promptly offer optimization suggestions. Upon your confirmation, we will proceed to craft a formal quotation, meticulously tailored to achieve your objectives.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier