Reliable Turbine Flowmeter with Stable Operation for Industrial Use

Product Details
Customization: Available
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
  • Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Find Similar Products
  • Overview
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang turbine flowmeter
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

 
Product Parameters
 
TK5100 turbine flow meter
Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Medium Measured Liquid without impurity,low viscosity,no strong corrosive action
Standards Executed Turbine flow sensor(JB/T9246-1999)
Calibration Specification Turbine flow meter(JJG1037-2008)
Instrument Caliber Flange connection type DN15-DN200
Thread connection type DN4-DN50
Clamping connection type DN4-DN200
Instrument Material 304 stainless steel,316(L)stainless steel,etc.
Flange Standard Conventional standards GB/T9113-2000
Other standards International flange
standards
Like German standard DIN,American standard ANSI,
Japanese standard JIS
Domestic pipe flange
standards
Like standards of Ministry of Chemical Industry,
Standards of Ministry of Machinery
Thread Specifications Conventional specifications Pipe thread of British system (external thread)
Other specifications Internal thread,spherical thread,NPT thread,etc.
Accuracy Class and
Corresponding
Repeatability

Accuracy class*1
±0.1%R ±0.5%R ±0.2%R(has to be
    customized)
Repeatability ≤0.15% ≤0.1% ≤0.03%
Range ratio 10:1~20:1
Output signal  Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
 Transmitter:two-wire system4~20mADC current signal
Power supply  Sensor:+12VDC,+24VDC(optional)
 Transmitter:+24VDC\220V
 Display type on site:3.6V lithium battery on the instrument
Signal Transmission Line STVPV3×0.3(three-wire system),2×0.3(two-wire system)
Transmission Distance ≤1000m
Signal Line Interface Basic type:Hausman joint,explosion-proof type:internal thread M20×1.5
Explosion Proof Class Basic type:not explosion proof,explosion-proof type:ExdlIBT6
Calibration Conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid flow calibration device with static mass approach
Environmental conditions Ambient temperature 20ºC
Relative humidity 65%
Operation Conditions
Medium temperature
T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC

Ambient temperature
Atmospheric pressure
-20ºC~+70ºC Relative humidity 5%~90%
86kPa~106kPa
TK5200 series plug-in liquid turbine flow meter
Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Measured Medium Large pipeline liquid like circulation water
Accuracy Class ±5%,±2.5%
Sensor Type Tangential type
Axial sensor
Structure Type  Integrated meter
Split type meter
Instrument Caliber and
Connection Type
Easy plug-in DN150-DN1100
Online plug-in DN150-DN1100
Pressure Class 1.6MPa
Meter Material Screw Stainless steel Impeller 2Cr13
  Flange Carbon steel Guide frame Stainless steel
Short section Ball valve
Plug-in type depth When the inner diameter of the pipeline (DN)≤1050mm,the plug-in depth is:
Tangential type 0.5×DN-20mm
Axial type 0.5×DN
Range ratio 10:1
Output signal Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
Transmitter:two-wire system 4~20mADC current signal
Power supply Sensor:+12VDC,+24VDC(optional)
Transmitter:+24VDC,220V
On-site display type:3.6V lithium battery on the instrument
Signal transmission line STVPV3×0.3(three-wire system),2×0.3 (two-wire system)
Transmission distance ≤1000m
Signal line connection port Basic type:Hausman joint,explosion proof:inner thread M20×1.5
Explosion proof class Basic type:not explosion proof,explosion proof:ExdIIBT6
Calibration conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid fow calibration device with static mass approach
Ambient conditions Ambient temperature 20ºC
Relative humidity 65%
Operation conditions  Medium temperature T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC
Ambient temperature -20ºC~+70ºC    Relative humidity 5%~90%
atmospheric    pressure 86kPa~106kPa
TK5300 Series Sanitary Liquid Turbine Flow Meter
Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Measurement medium Liquid for health care fields like food and liquor
Execution standards Turbine flow sensor(JB/T9246-1999)
Execution standards Turbine flow meter(JJG1037-2008)
Meter caliber and
connection method
Clamp connection type DN4-DN100
Accuracy class ±1%R,±0.5%R,±0.2%R
(to be made specially)
Instrument material Sensor 316(L)/304 stainless steel Guide frame 316/304
Impeller Dual phase steel 304
Range ratio 10:1~20:1
Pressure level 1.0MPa
Output signal Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
Transmitter:two-wire system 4~20mADC current signal
Power supply Sensor:+12VDC,+24VDC(optional)
 Transmitter:+24VDC\220V
 On-site display type:3.6V lithium battery on the instrument
Signal transmission line STVPV3×0.3 (three-wire system),2×0.3(two-wire system)
Transmission distance ≤1000m
Signal line connection port Basic type:Hausman joint,explosion proof:inner thread M20×1.5
Explosion proof class
Basic type:not explosion proof,explosion proof:ExdlIBT6
Calibration conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid flow calibration device with static mass approach
Ambient conditions Ambient temperature 20ºC
Relative humidity 65%
Operation Conditions Medium temperature T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC
Ambient temperature -20ºC~+60ºC Relative humidity 5%~90%
Atmospheric pressure 86kPa~106kPa
Company Profile
Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a radiant symbol of excellence within the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. group. Our unparalleled reputation for pioneering innovation and unwavering dedication elevates our prestigious status to unprecedented heights.
Established in the vibrant and ever-evolving cityscape of Shanghai in 2013, Cold Valley operates as a proud affiliate under the banner of Hanshan Intelligent Technology Co., Ltd. As a leader in the industry, we are acclaimed for our steadfast commitment to cutting-edge innovation and unmatched excellence.
Our distinguished team consists of founding experts hailing from prestigious international automation firms, amalgamating over two decades of profound experience in the fields of automation and engineering. With ten years of specialized expertise in consulting and digital solutions, we remain fervently dedicated to providing unparalleled automation and digitization products and services, all strategically coordinated from our state-of-the-art Shanghai headquarters.
With a treasured legacy extending beyond 20 years in the industry, we have adeptly carved a unique niche in the petrochemical domain. Our deep understanding of automation and digitalization requirements across all enterprise stages enables us to create customized products and solutions. Equipped with cutting-edge automation and digitalization advancements, we offer comprehensive life cycle services across a spectrum of industries, including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Reliable Turbine Flowmeter with Stable Operation for Industrial Use
Reliable Turbine Flowmeter with Stable Operation for Industrial Use

Reliable Turbine Flowmeter with Stable Operation for Industrial UseReliable Turbine Flowmeter with Stable Operation for Industrial UseReliable Turbine Flowmeter with Stable Operation for Industrial UseReliable Turbine Flowmeter with Stable Operation for Industrial UseReliable Turbine Flowmeter with Stable Operation for Industrial Use

Reliable Turbine Flowmeter with Stable Operation for Industrial UseReliable Turbine Flowmeter with Stable Operation for Industrial Use

Frequently Asked Questions

How to Choose the Right Product?
A: Upon receiving your inquiry, we promptly provide you with a detailed technical document, allowing for a thorough evaluation of essential process parameters and technical specifications. Guided by your unique requirements, we recommend the most fitting model, precisely tailored to meet your distinct needs with the utmost accuracy.

Desire a Confirmed Model?

A: Absolutely. Once you furnish us with your model specification, we meticulously confirm its suitability and offer further cost-efficient optimization suggestions as needed. Following your confirmation, we proceed to craft a comprehensive and detailed formal quotation, meticulously tailored for your consideration.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier