The Rosemount 5301 Level Transmitter stands as the epitome of excellence in tackling the most demanding measurements of liquids, slurries, and solids. It boasts unrivaled reliability and cutting-edge safety features tailored for both level and interface applications. Experience the seamless integration of Rosemount 5301, where installation is a breeze, calibration is a thing of the past, and performance is undeterred by fluctuating process conditions. Its SIL 2 certification elevates it as the premier choice for safety-critical applications. With robust construction and powerful built-in diagnostics, you can concentrate on what truly matters - optimizing your plant's performance.
Measuring Medium |
Liquid |
Defined Range |
2000mm |
Type |
Guided Wave Radar Level |
Wetted Material |
316L |
Accuracy |
3MM or 0.03% |
Steam Jacket |
NO |
Operating Pressure |
-0.1~34.5Mpa |
Jacket Pressure |
NO |
Operating Temperature |
-60~400°C |
Instrument Power |
24V |
Electric Connect |
Flange |
Signal Output |
4-20MA |
Connection diameter |
DN50 |
Display |
YES |
Flange Material |
316L |
Electrical Interface |
1/2"NPT |
Flange Size |
DN50 |
Protocol |
Hart |
Flange Pressure |
300lb |
Protection Level |
IP67 |
Flange Face |
RF |
Explosion Proof |
ExiaIICT6 |
Flange Standard |
ANSI 2" 300RF |
Warranty |
1year |
Accuracy:±0.12 in. (3 mm)
Repeatability:±0.04 in. (1 mm)
Measurement Range:Up to 164 ft (50 m)
Operating Pressure:Full vacuum to 5000 psi (Full vacuum to 345 bar)
Operating Temperature:-320 to 752 °F (-196 to 400 °C)
Communication Protocol:4-20 mA/HART™, Foundation™ Fieldbus, Modbus™
Safety:SIL 2 IEC 61508 certification
TÜV tested and WHG approved for overfill prevention
Experience the convenience of remote proof-test capabilities through an innovative verification reflector
Diagnostics:Unlock enhanced diagnostics, empowering you to engage in proactive maintenance
Probe Types:Choose from a diverse array of probe types including Rigid single lead, Segmented single lead, Flexible single lead, Rigid twin lead, Flexible twin lead, Coaxial and large coaxial, PTFE coated probes, and Vapor probe
Enhanced Performance:Harness Direct Switch Technology for unparalleled sensitivity, unmatched reliability, and extended measurement ranges
Proactive Maintenance:Leverage Signal Quality Metrics to take charge of your level instrumentation proactively
Improved Accuracy:Utilize Probe End Projection for superior level measurement reliability
Optimized Efficiency:Benefit from Dynamic Vapor Compensation for enhanced plant heat rate efficiency
Simplified Verification:Experience the ease of remote proof-testing with a verification reflector for unique level transmitter verification
Advanced Detection:Achieve ultra-thin layer detection through state-of-the-art Peak-in-Peak technology
Dimension
Flexible Single Lead Probe with Flange Connection
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
A. Secure your setup with a robust ½ - 14 NPT connection, offering adaptable options with M20x1.5, eurofast, and minifast adapters.
B. Experience versatility with a lead length reaching up to an impressive 164 ft. (50 m), catering to extensive measurement needs.
C. Enjoy precision with diameter options of Ø 0.16 (4) or Ø 0.24 (6), customized for your specific applications.
D. Choose between a 4 mm probe with a compact Ø 0.86 (22) or a 6 mm probe with a robust Ø 1.10 (28) for enhanced accuracy.
E. The PTFE-covered probe is ingeniously designed with a protective plate, ensuring durability and optimal performance.
F. The PTFE-covered probe offers a diameter of Ø 0.28 (7), providing a sleek and efficient measurement solution.
G. Boasting a length of 17.1 (434) specifically for the PTFE-covered probe, it's engineered for superior reach and effectiveness.
H. Featuring a diameter of Ø 0.88 (22.5), the PTFE-covered probe is crafted for precision and reliable performance.
I. Available in HTHP/HP/C versions, ensuring adaptability and reliability in high temperature and high pressure environments.
J. The HTHP/HP/C Plate Design is an optional feature for alloy versions, enhancing flexibility and performance.
K. Opt for the short weight (option W2) to accommodate specific operational requirements with ease.
L. Select the heavy weight (option W3) for a more robust and stable operational setup.
M. Includes a chuck for secure and effective component fastening, ensuring system integrity.
Dimensions are presented in inches (millimeters), ensuring clear and concise measurement standards.
Company Profile
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a proud affiliate of the esteemed Hanshan (Cold Mountain) Intelligent Technology Co. group.
Hanshan Intelligent Technology Co., Ltd. was officially established in the bustling city of Shanghai in 2013, marking the beginning of a new era in technological prowess.
Our founding team is composed of experts hailing from prestigious international automation companies. With over 20 years of rich experience in the automation industry and engineering, and more than a decade dedicated to consulting and implementing digital solutions, we are committed to delivering top-tier automation and digitization products and services to clients worldwide. Our global headquarters proudly reside in Shanghai, China.
For over 20 years, we have been deeply ingrained in the petrochemical industry, acquiring profound insights into the automation and digitalization demands of enterprises spanning upstream, midstream, and downstream sectors. We offer an array of expert products and solutions tailored to meet automation and digitalization needs, coupled with comprehensive life cycle services for industries including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
![Rosemount 5301 Transmitter: High-Performance Guided Wave Radar for Liquid Measurement](//www.micstatic.com/athena/img/transparent.png)
You may have these questions
How do I choose the perfect product for my needs?
A:Upon receiving your inquiry, we will equip you with an all-encompassing technical document, enabling you to scrutinize the intricate process parameters and technical specifications essential for your project. Based on your particular needs, we will recommend the most fitting model tailored to your specifications.
I am interested in receiving a confirmed model. Is that possible?
A:Absolutely. Once you provide us with the model of interest, we will first ascertain its compatibility and suitability. Should there be a need, we will offer additional cost-effective optimization suggestions. Following validation, we can advance with a formal quotation.