Customization: | Available |
---|---|
Task: | Adjust |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Excellent control performance
- Adopts sensorless vector control for superior performance.
- Features both static and rotating motor parameter auto-tuning.
2. Optimized structural design
- Compact dimensions save valuable installation space.
3. Rich configuration and interfaces, powerful functionality
- Standard built-in RS485 communication port with multiple I/O terminals and detachable keypad interface for flexible field applications.
- Built-in DC reactor (standard for 18.5-110kW models) improves power factor.
- Integrated braking unit (standard for ≤37kW models; optional for 45-110kW models).
4. Multiple installation methods
- 380V 2.2kW and lower models support both DIN rail mounting and wall mounting; 380V 4kW and above models support wall mounting and flange mounting.
5. Ease of use and maintenance
- Independently removable cooling fan facilitates maintenance.
- Standard configuration includes an external LED keypad; supports optional LED keypad with parameter copy function available for diverse application needs.
6. Integrated functions for versatile applications
- Includes basic PLC, multi-speed control, built-in PID, torque control, multi-point V/F curves, multiple braking methods, ride-through for power loss, and more.
Function | Specification | |
Power input | Input voltage (V) | AC 1PH 220V (-15%)-240V (+10%) AC 3PH 220V (-15%)-240V (+10%) |
Function | Specification | |
AC 3PH 380V (-15%)-440V (+10%) | ||
Input current (A) | Refer to section2.5"Rated specifications" | |
Input frequency (Hz) | 50Hz or 60Hz; allowed range: 47-63Hz | |
Power output |
Output voltage (V) | 0-input voltage |
Output current (A) | Refer to section2.5"Rated specifications" | |
Output power (kW) | Refer to section2.5"Rated specifications" | |
Output frequency (Hz) |
0-400Hz | |
Technical control feature |
Control mode | SVPWM, SVC |
Motor | Asynchronous motor | |
Adjustable-speed ratio |
Asynchronous motor 1: 100 (SVC) | |
Speed control accuracy |
±0.2% (SVC) | |
Speed fluctuation | ± 0.3% (SVC) | |
Torque response | <20ms (SVC) | |
Torque control accuracy |
10% | |
Starting torque | 0. 5Hz/150% (SVC) | |
Overload capability | 150% of rated current: 1 minute 180% of rated current: 10 seconds 200% of rated current: 1 second |
|
Running control feature |
Frequency setting method |
Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, Modbus communication setting Shift between the set combination and set channel. |
Auto-adjustment of the voltage |
Keep a stable voltage automatically when the grid voltage transients | |
Fault protection | Provide comprehensive fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss and overload, etc. | |
Start after speed tracking |
Smoothing starting for running motor | |
Peripheral interface |
Analog input | 1 (AI2) 0-10V/0-20mA and 1 (AI3) -10-10V |
Analog output | 2 (AO1, AO2) 0-10V/0-20mA | |
Digital input | 4 common inputs, and max. frequency: 1kHz; 1 high speed input, and max. frequency: 50kHz |
|
Digital output | 1 Y1 terminal output |
Function | Specification | |
Relay output |
2 programmable relay outputs RO1A NO, RO1B NC, RO1C common terminal RO2A NO, RO2B NC, RO2C common terminal Contact capacity: 3A/AC250V, 1A/DC30V |
|
Others |
DC reactor | DC reactors have been built in the 18.5kW and higher VFD models as standard configuration. |
Installation mode |
Wall and rail installation for the 1PH 220V/3PH 380V (≤2.2KW) and 3PH 220V (≤0.75KW) VFD models Wall and flange installation for the 3PH 380V (≥4kW) and 3PH 220V (≥1.5kW) VFD models |
|
Braking unit |
Braking units have been built in the 37kW and lower VFD models as standard configuration. Braking units have been built in the 45-110kW VFD models as optional configuration. | |
EMI filter |
3PH 380V (≥4kW) and 3PH 220V (≥1.5kW) VFD models can satisfy the requirements of IEC 61800-3 C3, other models can satisfy the requirements of IEC 61800-3 C3 by installing optional external filter. The whole series can satisfy the requirements of IEC 61800-3 C2 by installing optional external filter. | |
Ambient environment |
-10 to 50°C, derate 1% for every additional 1°C when above 40°C. | |
Altitude |
When the altitude exceeds 1000m, derate by 1% for every increase of 100m. When the altitude exceeds 3000m, consult the local INVT dealer or office for details. |
|
Protective degree |
IP20 Note: The VFD with plastic casing should be installed in metal distribution cabinet, which conforms to IP20 and of which the top conforms to IP3X. |
|
Pollution level | Level 2 | |
Safety | Meet the requirement of CE | |
Cooling mode | Forced air cooling. |
Key | No. | Detailed description |
Detailed content |
Abbreviation of product series |
Abbreviation of product series |
GD20: Goodrive20 series VFD | |
Rated power | Power range + Load type |
2R2: 2.2kW G: Constant torque load |
|
Voltage class | Voltage class | S2: AC 1PH 220V (-15%)-240V (+10%) 2: AC 3PH 220V (-15%)-240V (+10%) 4: AC 3PH 380V (-15%)-440V (+10%) |
|
Note: Braking units have been built in the 37kW and lower VFD models as standard configuration. Braking units are not standard configuration for the 45-110kW VFD models. (If you want to use braking units for these models, add suffix "-B" at the end of the model codes in your purchase orders, for example, GD20-045G-4-B.) |
Model | Voltage class |
Rated output power (kW) |
Rated input current (A) |
Rated output current (A) |
GD20-0R4G-S2 | 1PH 220V |
0.4 | 6.5 | 2.5 |
GD20-0R7G-S2 | 0.75 | 9.3 | 4.2 | |
GD20-1R5G-S2 | 1.5 | 15.7 | 7.5 | |
GD20-2R2G-S2 | 2.2 | 24 | 10 | |
GD20-0R4G-2 | 3PH 220V |
0.4 | 3.7 | 2.5 |
GD20-0R7G-2 | 0.75 | 5 | 4.2 | |
GD20-1R5G-2 | 1.5 | 7.7 | 7.5 | |
GD20-2R2G-2 | 2.2 | 11 | 10 | |
GD20-004G-2 | 4 | 17 | 16 | |
GD20-5R5G-2 | 5.5 | 21 | 20 | |
GD20-7R5G-2 | 7.5 | 31 | 30 | |
GD20-0R7G-4 | 3PH 380V |
0.75 | 3.4 | 2.5 |
GD20-1R5G-4 | 1.5 | 5.0 | 4.2 | |
GD20-2R2G-4 | 2.2 | 5.8 | 5.5 | |
GD20-004G-4 | 4 | 13.5 | 9.5 | |
GD20-5R5G-4 | 5.5 | 19.5 | 14 | |
GD20-7R5G-4 | 7.5 | 25 | 18.5 | |
GD20-011G-4 | 11 | 32 | 25 | |
GD20-015G-4 | 15 | 40 | 32 | |
GD20-018G-4 | 18.5 | 47 | 38 | |
GD20-022G-4 | 22 | 51 | 45 | |
GD20-030G-4 | 30 | 70 | 60 | |
GD20-037G-4 | 37 | 80 | 75 | |
GD20-045G-4 | 45 | 98 | 92 | |
GD20-055G-4 | 55 | 128 | 115 | |
GD20-075G-4 | 75 | 139 | 150 | |
GD20-090G-4 | 90 | 168 | 180 | |
GD20-110G-4 | 110 | 201 | 215 |
Serial No. |
Name | Description |
1 | External keypad port | Connect the external keypad |
2 | Port cover | Protect the external keypad port |
3 | Cover | Protect the internal parts and components |
4 | Hole for the sliding cover | Fix the sliding cover |
5 | Trunking board | Protect the inner components and fix the cables of the main circuit |
6 | Product nameplate | See section 2.3 "Product nameplate" for detailed information |
7 | Potentiometer knob | Refer toChapter 4"Keypad operation" |
8 | Control terminals | SeeChapter 3"Installation guidelines" for detailed information |
9 | Main circuit terminals | SeeChapter 3"Installation guidelines" for detailed information |