Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available

Product Details
Customization: Available
Type: Wall-Mounted Current Type
Measuring Medium: Temperature
Diamond Member Since 2024

Suppliers with verified business licenses

Registered Capital
5000000 RMB
Plant Area
101~500 square meters
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
  • Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Find Similar Products
  • Overview
  • Dimension
  • Company Profile
Overview

Basic Info.

Model NO.
248HUI7A2XAP
Display Type
LCD
Site Display
Not Site Display
Accuracy
±0.2°c
IP Rating
IP65
Certification
CE
Customized
Customized
Opere Temperature
-20~80ºC
Supply Voltage
24VDC
Range
-200~850°c
Output Signal
4-20mA
LCD Display
Yes
Electric Connect
1/2"NPT
Protocol
Hart
Explosion
IEC Exia Iic T4
Insert Length
Customizable
Thermowell Diameter
5~11mm
Thermowell Material
316L
Extended
80 or Customized
Transport Package
Wooden
Trademark
Rosemount
Origin
China
HS Code
90262010
Production Capacity
50000peices/Years

Product Description


An industry-standard solution, the Rosemount 248 Temperature Transmitter delivers consistent and reliable performance for process environments. Engineered to meet requirements for common single point temperature measurement applications, its durable design withstands a wide range of process environments. For application flexibility, this head mount temperature transmitter is available with a variety of housing options.
Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Input:Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)

Output:Signal4-20 mA /HART™ protocol

Housing:DIN B head mount

Diagnostics:Basic diagnostics including open/short sensor diagnostics

Calibration Options:5-point calibration

Certifications/Approvals:SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, etc.
 
Standard Transmitter: Standard transmitter meets common single point temperature measurement application requirements

Superior Housing Resistance: Housing construction provides superior resistance to many process environments

One-Year Stability Rating:  One-year stability rating reduces maintenance costs

Open/Short Sensor Diagnostics:Open/short sensor diagnostics help detect issues in the sensor loop to ensure reliable performance

Device Dashboards:Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

Transmitter-Sensor Matching:Transmitter-sensor matching with Callendar-Van Dusen constants reduces total measurement error
Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Model Product description
248  Temperature transmitter  
Transmitter type
H DIN B Head Mount
Transmitter output
A 4-20 mA with digital signal based on HART Protocol
Product certifications Enclosure option codes
permitted
 
E5 FM Explosion-Proof A, U, G, H
I5 FM Intrinsic Safety and Class I, Division 2 A, B, U, N,G, S, H
K5 FM Intrinsic Safety, Explosion-Proof, and Class I, Division 2 A, U, G, H
I6 CSA Intrinsic Safety and Class I, Division 2 A, B, U, N,G, H
K6 CSA Intrinsic Safety, Explosion-Proof, and Class I, Division 2 A, U, G, H
E1 ATEX Flameproof A, U, G, H
I1 ATEX Intrinsic Safety A, B, U, N,C,G,S, H
ND ATEX Dust A, U, G, H
N1 ATEX Type n A, U, G, H
NC ATEX Type n Component N
E7 IECEx Flameproof and Dust A, U, G, H
I7 IECEx Intrinsic Safety All options
N7 IECEx Type n A, U, G, H
NG IECEx Type n Component N
KM Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety A, U, G, H
IM Technical Regulations Customs Union (EAC) Intrinsic Safety All options
EM Technical Regulations Customs Union (EAC) Flameproof A, U, G, H
E3 China Flameproof A, G, H, N
I3 China Intrinsic Safety A, G, H, N
N3 China Type n A, U, G, H
NA No Approval All options
Enclosure Material IP rating  
A Connection head Aluminum IP66/68
B BUZ head Aluminum IP65
C BUZ head Polypropylene IP65
G Connection head SST IP66/IP68
H Universal head (junction box) SST IP66/IP68
U Universal head (junction box) Aluminum IP66/IP68
N No enclosure N/A N/A
F Sanitary connection head, DINA Polished SST IP66/IP68  
S Sanitary connection head, DIN B Polished SST IP66/IP68  
Conduit entry size
M20 × 1.5 (CM20)
1/2-in. NPT
No enclosure
Assemble to options
XA Sensor specified separately and assembled to transmitter
NS No sensor
 
Rosemount 248R Rail Mount Transmitter  
Model Product description
248R Rail mount temperature transmitter  
Output protocol
A 4-20 mA with digital signal based on HART Protocol
Product certifications
I5 FM Intrinsically Safe and Class I, Division 2
I6 CSA Intrinsically Safe and Class I, Division 2
I1 ATEX Intrinsic Safety
NC ATEX Type n Component
I7 IECEx Intrinsic Safety
IM GOST (Russia) Intrinsically Safe
NA No Approvals
Dimension

 

 Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Company Profile
Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. is a member enterprise of Hanshan (Cold Mountain) Intelligent Technology Co;
 (hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) was formally established in Shanghai in 2013;
Its founding team are all from top international automation companies; have over 20 years of experience in automation industry; over 20 years of experience in automation engineering; over 10 years of experience in consulting and implementation of digital solutions; aiming at providing quality automation and digitization products and services for global customers; the company's headquarter is located in Shanghai, China;
The company has been deeply cultivated in the petrochemical industry for more than 20 years; has in-depth understanding of the automation and digitalization needs of upstream, midstream, and downstream enterprises; provides professional products and solutions based on automation and digitalization and full life cycle services for petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available
Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available

Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes AvailableRosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes AvailableRosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes AvailableRosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes AvailableRosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available

Rosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes AvailableRosemount Temperature Transmitter Accuracy ± 0.2° C for Single Point Temperature Measurement with Hard and Hygienic Junction Boxes Available

You may have this questions

How do I select the right product?
A:Upon receipt of your inquiry, we will provide you with a comprehensive technical document. This will enable you to verify the detailed process parameters and technical specifications required. Based on your specific requirements, we will then recommend the most suitable model.

I would like a confirmed model. Can you provide that?
A:Certainly. Once you send us the model you require, we will first need to verify the suitability of the model. If necessary, we will provide some more cost-effective optimization suggestions. After confirmation, we can proceed with a formal quotation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier