Overload Capability Inverter for Independent Air Duct Design Systems

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (10)
  • Overload Capability Inverter for Independent Air Duct Design Systems
  • Overload Capability Inverter for Independent Air Duct Design Systems
  • Overload Capability Inverter for Independent Air Duct Design Systems
  • Overload Capability Inverter for Independent Air Duct Design Systems
  • Overload Capability Inverter for Independent Air Duct Design Systems
  • Overload Capability Inverter for Independent Air Duct Design Systems
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
GD200A-004G/5R5P-4
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control
Certification
RoHS, CCC, CE
Condition
New
Customized
Non-Customized
Material
Aluminum Alloy
Principle of Work
V/F Control Transducer
Main Circuit Type
Voltage
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Voltage of Power Supply
Medium Voltage Variable-Frequency Drive
Switch Mode
High Carrier Frequency PWM Control
Product
100% Original
Transport Package
Wooden
Trademark
invt
Origin
China
HS Code
85044099
Production Capacity
50000peices/Years

Product Description

Product Description

GD200A Series General Purpose Drives


Introducing the GD200A, a powerhouse in the realm of variable frequency drives (VFD)! With an expansive power range from 0.75kW to an impressive 3000kW, this general-purpose VFD is a testament to efficiency and durability. Trusted by numerous industries, from municipal engineering to metal processing, chemical, steel, papermaking, petroleum, HVAC, and food processing, the GD200A has surpassed expectations with over one million units transforming operations across the globe. Its reliability is unmatched, setting new standards in versatile industrial applications.

1. Versatile and ease of use
- Experience seamless installation with options for wall, flange, and floor mounting-ensuring adaptability to your specific project needs.
- Embrace flexibility with support for common DC bus and DC power supply modes, optimizing your energy solutions.
- Benefit from tailored functionalities including a dedicated water supply mode, straightforward PLC programming, and advanced speed tracking, making your processes more efficient.

2. Stable and reliable
- Crafted with an independent air duct design and enhanced conformal coating, the GD200A is built to thrive in challenging environments, protecting circuit boards from harsh conditions.
- Comes standard with a built-in C3 filter to minimize electromagnetic interference, and offers an optional external C2 filter for added protection.

3. Multi-certification compliance
- The GD200A proudly holds certification from CE, UKCA, and EAC, ensuring it meets global safety and quality standards.
- It aligns with the IEC/EN 61800-9-2 energy efficiency standards, affirming its eco-friendly design.

Overload Capability Inverter for Independent Air Duct Design Systems
 
Overload Capability Inverter for Independent Air Duct Design Systems
Structure diagram

Below is the VFD layout figure (taking the 030G/037P model for example).
Serial
No.
Name Illustration
1 Keypad port Connect the keypad
2 Upper cover Protect the internal parts and components
3 Keypad See5.4Keypad operationfor detailed information
4 Cooling fan See 8.8Maintenance  and  hardware  diagnostics  for detailed information
5 Wires port Connect to the control board and the drive board
6 Nameplate See3Product overviewfor detailed information

7

Side cover
Optional part. The side cover will increase the protective degree of the VFD. The internal temperature of the VFD will increase, too, so it is necessary to derate the VFD at the same time
8 Control terminals See4Installation guidelinesfor detailed information
9 Main circuit terminals See4Installation guidelinesfor detailed information
10 Main circuit cable entry Fix the main circuit cable
11 POWER light Power indicator
12 Simple nameplate See3Product overviewfor detailed information
13 Lower cover Protect the internal parts and components





Overload Capability Inverter for Independent Air Duct Design Systems
Product specification
Function Specification

Input
Input voltage (V) AC 3PH 380V(-15%)-440V(+10%)
Input current (A) SeeRated specifications.
Input frequency (Hz) 50Hz or 60Hz
Allowed range: 47-63Hz

Output
Output voltage (V) 0-Input voltage
Output current (A) SeeRated specifications.
Output power (kW) SeeRated specifications.
Output frequency (Hz) 0-400Hz






Technical
control
feature
Control mode SVPWM, SVC
Motor type Asynchronous motor
Speed ratio Asynchronous motor 1: 100 (sensorless vector control)
Speed control accuracy ±0.2% (sensorless vector control)
Speed fluctuation ±0.3%(sensorless vector control)
Torque response <20ms(sensorless vector control)
Torque control accuracy 10%(sensorless vector control)
Starting torque Asynchronous motor: 0.5Hz/150% (SVC)



Overload capability
G type:
150% of rated current: 1 minute
180% of rated current: 10 seconds 200% of rated current: 1 second
P type:
120% of rated current: 1 minute
150% of rated current: 10 seconds
180% of rated current: 1 second



Running
control
feature

Frequency setting
Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting,   PID setting, MODBUS communication setting.
Shift between the set combination and set channel.
Auto voltage adjustment Keep a stable voltage automatically when the grid voltage transients

Fault protection
Provide over 30 fault protection functions: overcurrent,   overvoltage, undervoltage, overheating, phase loss and overload, etc.
Function Specification
 
Speed tracking
Restart the rotating motor smoothly
Note: This function is available for the 004G/5R5P and higher models.







Peripheral
interface
Terminal analog input resolution  20mV
Terminal switch input
resolution
 2ms
Analog input 1 channels ( AI2) 0 (2)-10V/0 (4)-20mA and 1 channel (AI3) -10-10V
Analog output 2 channels (AO1, AO2) 0 (2)-10V /0 (4)-20mA

Digital input
8 channels common input, max. frequency: 1kHz, internal impedance: 3.3kΩ;
1 channel high speed input, max. frequency:    50kHz

Digital output
1 channel high speed pulse output, max. frequency: 50kHz;
1 channel Y terminal open collector pole output

Relay output
2 channels programmable relay output
RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal Contactor capability: 3A/AC250V,1A/DC30V






Others
Mountable method Wall, flange and floor mountable
Temperature of the running environment -10-50°C, derating is required if the temperature is
above 40°C. If the ambient temperature is above 40°C, derate 1% for every additional 1°C.
Ingress protection IP20
Cooling Air-cooling
Pollution level Level 2
Braking unit Built in 030G/037P and lower models.For other models, it is an optional part.

EMC filter
380V series products can meet the requirements of IEC61800-3 C3
External optional filter: meet the requirement of IEC61800-3 C2


Product nameplate
Overload Capability Inverter for Independent Air Duct Design Systems

Figure Product nameplate
Note: This is a nameplate example of a standard VFD product. The CE/TUV/IP20 marking on the top right will be marked according to actual certification conditions.

Model code
Note: This is the example of the nameplate for the standard products, and CE\TUV\IP20 will be marked according to the actual situations.
3.5 Type designation key
The type designation contains information on the VFD. The user can find the type designation on the type designation label attached to the VFD or the simple nameplate.
GD200A-011 G/015 P-4
Figure Product type
Key Instruction
  GD200A : abbreviation of Goodrive200A
  3-digit code: output power. "R" means the decimal point; "011": 11kW; "015": 15kW
  G: Constant torque load
P: Variable torque load
  Input voltage degree:
4: AC 3PH 380V(-15%)-440V(+10%)
3.6 Rated specifications

VFD model
Constant torque Variable torque
Output
power
(kW)
Input
current
(A)
Output
current
(A)
Output
power
(kW)
Input
current
(A)
Output
current
(A)
GD200A-0R7G-4 0.75 3.4 2.5 / / /
GD200A-1R5G-4 1.5 5.0 3.7 / / /
GD200A-2R2G-4 2.2 5.8 5 / / /

VFD model
Constant torque Variable torque
Output
power
(kW)
Input
current
(A)
Output
current
(A)
Output
power
(kW)
Input
current
(A)
Output
current
(A)
GD200A-004G/5R5P-4 4 13.5 9.5 5.5 19.5 14
GD200A-5R5G/7R5P-4 5.5 19.5 14 7.5 25 18.5
GD200A-7R5G/011P-4 7.5 25 18.5 11 32 25
GD200A-011G/015P-4 11 32 25 15 40 32
GD200A-015G/018P-4 15 40 32 18.5 47 38
GD200A-018G/022P-4 18.5 47 38 22 56 45
GD200A-022G/030P-4 22 56 45 30 70 60
GD200A-030G/037P-4 30 70 60 37 80 75
GD200A-037G/045P-4 37 80 75 45 94 92
GD200A-045G/055P-4 45 94 92 55 128 115
GD200A-055G/075P-4 55 128 115 75 160 150
GD200A-075G/090P-4 75 160 150 90 190 180
GD200A-090G/110P-4 90 190 180 110 225 215
GD200A-110G/132P-4 110 225 215 132 265 260
GD200A-132G/160P-4 132 265 260 160 310 305
GD200A-160G/185P-4 160 310 305 185 345 340
GD200A-185G/200P-4 185 345 340 200 385 380
GD200A-200G/220P-4 200 385 380 220 430 425
GD200A-220G/250P-4 220 430 425 250 485 480
GD200A-250G/280P-4 250 485 480 280 545 530
GD200A-280G/315P-4 280 545 530 315 610 600
GD200A-315G/355P-4 315 610 600 355 625 650
GD200A-355G/400P-4 355 625 650 400 715 720
GD200A-400G-4 400 715 720 / / /
GD200A-450G-4 450 840 820 / / /
GD200A-500G-4 500 890 860 / / /
Note:
1. The input current of the 0R7G-315G/355P models is measured when the input voltage is 380V and no DC reactor and input/output reactor.
2. The input current of the 355G/400P-500G models is measured when the input voltage is 380V and the circuit is with input reactor.
3. The rated output current is defined as the output current when the output voltage is 380V.
4. In the allowable voltage range, the output power and current cannot exceed the rated output power and current in any situation.

 

 
 
 
 
 
Company Profile
Overload Capability Inverter for Independent Air Duct Design Systems
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. shines as a beacon of ingenuity and excellence, proudly representing the Hanshan (Cold Mountain) Intelligent Technology Co. family. It stands at the pinnacle of innovation, consistently delivering exceptional performance.
As a vital part of the Hanshan Intelligent Technology Co., Ltd. group, we embarked on our remarkable journey in the dynamic and ever-evolving metropolis of Shanghai in 2013. This milestone marked a new dawn of technological advancement infused with a bold entrepreneurial spirit.
Our visionary founding team comprises esteemed industry veterans sourced from the upper tiers of global automation leadership. They boast an impressive fusion of over 20 years of automation engineering prowess and a decade of consultancy excellence in deploying cutting-edge digital solutions. Driven by an unwavering commitment, they aim to offer unparalleled automation and digitization services that enthrall a global clientele. Nestled in the vibrant heart of Shanghai, China, the company stands as a testament to extraordinary technological expertise and forward-thinking innovation.
With a remarkable two-decade legacy in the petrochemical sector, our company has gleaned deep understanding of the intricate automation and digitalization needs across the entire industry spectrum - upstream, midstream, and downstream. We deliver meticulously engineered products and comprehensive solutions, tailor-made for diverse sectors, including petroleum, chemical, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, guaranteeing exceptional performance and unmatched quality throughout the entire product lifecycle.
Overload Capability Inverter for Independent Air Duct Design Systems

Overload Capability Inverter for Independent Air Duct Design SystemsOverload Capability Inverter for Independent Air Duct Design SystemsOverload Capability Inverter for Independent Air Duct Design SystemsOverload Capability Inverter for Independent Air Duct Design SystemsOverload Capability Inverter for Independent Air Duct Design Systems

Overload Capability Inverter for Independent Air Duct Design SystemsOverload Capability Inverter for Independent Air Duct Design Systems
FAQ
You may have these questions

How do I select the right product?
A: Upon receiving your inquiry, our comprehensive technical dossier will provide all the necessary insights. This documentation will enable you to thoroughly verify the process parameters and technical specifications pertinent to your needs. With this information, we will expertly recommend the model that precisely aligns with your specific requirements.

I would like a confirmed model. Can you provide that?
A: Certainly. Once you communicate the model you are interested in, we will conduct a thorough verification process to ensure its suitability. If there are opportunities for cost-effective enhancements, we will gladly offer optimization suggestions. After your confirmation, we will proceed with crafting a formal quotation, tailored to meet your objectives.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now