Customization: | Available |
---|---|
Accuracy: | ±0.2-0.5% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas |
Suppliers with verified business licenses
Model | TK1100 standard series | TK1200 high accuracy series |
Caliberl | DN3-DN2200 | DN10-DN300 |
Accuracy | 0.5% | 0.2%,0.3% |
Installation method | Hold,flange | Hold,flange |
Repeatability | 0.1% | 0.06%,0.1% |
Measuring range | 0-12m/s(flow unit can be changed) | 0-12m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | GB/T9119-2000 or any other choice |
Pressure | 4.0MPa~0.25 Mpa (classify by caliber) |
4.0MPa~0.25 Mpa (classify by caliber) |
Lining material | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard,(scraper,it can be replaced by DN>350) | Standard,(scraper,it can be replaced by DN>350) |
Protection level of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >5μS/cm(water>20μS/cm) | >2μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) | Integrated type≤90ºC,split type≤160ºC(rubber) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | Integrated,split | Integrated,split |
Output signal | 4-20mA current signal,frequency /pulse output | 4-20mA current signal,frequency/pulse output |
Power supply | AC:85V~265V,DC:18V~36V | AC:85V~265V,DC:18V~36V |
Self diagnosis | yes | yes |
Zero setting of empty pipe | yes | yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,HART,PROFIBUS |
Explosion-proof | No explosion proof/explosion proof | No explosion proof/explosion proof |
Language | Chinese,English | Chinese,English |
Product standards | JB/T 9248-1999 | JB/T 9248-1999 |
Model | TK1300 hygienic series | TK1500 battery powered series |
Caliberl | DN3-DN150 | DN10-DN1200 |
Accuracy | 0.2%,0.5% | 0.5% |
Installation method | Thread,clamp | Hold,flange |
Repeatability | 0.06%,0.1% | 0.15% |
Measuring range | 0-12m/s(flow unit can be changed) | 0-10m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | |
Pressure | The highest 4.0MPa | 4.0MPa~0.6 Mpa (classify by caliber) |
Lining material | PFA(negative pressure resistance) | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard | Standard,(scraper,it can be replaced by DN>350) |
Protection leve of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >2μS/cm(water>20μS/cm) | >5μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤160ºC | Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | ntegrated,split | Lntegrated,split |
Output signal | 4-20mA current signal,frequency/pulse output | Frequency 0-5kHz |
Power supply | AC:85V~265V,DC:18V~36V | 3.6V |
Self diagnosis | Yes | Yes |
Zero setting of empty pipe | Yes | Yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,GPRS |
Explosion-proof | No explosion proof/explosion proof | |
Language | Chinese,English | Chinese,English |
Product standards | JB/T 9248-1999 |
Model | TK1400 inserted type series | TK1600 electromagneticheat meter series |
Caliberl | DN200-DN3000 | DN15-DN1200 |
Accuracy | 1.5%;2.5% | 1.0%,2.0%,2.5% |
Installation method | Flange,thread,on-line | Hold,flange,thread |
Repeatability | 0.5% | 0.3%;0.5% |
Measuring range | 0-10m/s(flow unit can be changed) | 0-12m/s(flow unit can be changed) |
Connecting flange | GB/T9119-2000 or any other choice | GB/T9119-2000 or any other choice |
Pressure | 1.6MPa | 4.0MPa~0.6Mpa (classify by caliber) |
Lining material | POM,PTFE,PFA | PO,PTFE,PFA(negative pressure resistance), rubber,polyurethane) |
Electrode material | 316L,HC,HB,titanium,tantalum,platinum | 316L,HC,HB,titanium,tantalum,platinum |
Electrode form | Standard | Standard |
Protection level of sensor | IP65,IP67,IP68 | IP65,IP67,IP68 |
Conductivity | >5μS/cm(water>20μS/cm) | >5μS/cm(water>20μS/cm) |
Maximum temperature of medium | Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) | Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC) |
Ambient maximum temperature | -30ºC~+65ºC | -30ºC~+65ºC |
Converter installation mode | Integrated,split | Integrated,split |
Output signal | 4-20mA current signal,frequency/pulse output | 4-20mA current signal,frequency /pulse output |
Power supply | AC:85V~265V,DC:18V~36V | AC:85V~265V,DC:18V~36V |
Self diagnosis | Yes | yes |
Zero setting of empty pipe | Yes | yes |
Communication | RS485/Modbus,HART,PROFIBUS | RS485/Modbus,HART,PROFIBUS |
Explosion-proof | No explosion proof/explosion proof | No explosion proof/explosion proof |
Language | Chinese,English | Chinese,English |
Product standards | Refer to 9248-1999 JB/T |