Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Year of Establishment
2024-11-19
Plant Area
50 square meters
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Find Similar Products
  • Overview
  • Technical Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang electromagnetic flowmeter
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

It uses the international leading excitation technology. The 
excitation circuit is simple, stable and reliable, it has the 
performance of artificial intelligence. 
There are no movable parts and no resisting flow parts in the 
pipeline. 
There is no additional pressure-loss. The measurement results 
have no relationship to flow velocity distribution, fluid pressure, 
temperature, density, viscosity and other physical parameters. 
It can modify the range online according to the actual need of users . 
It can be used to measure the flow of conductive fluid,such as tap 
water, sewage, mud, all kinds of drinks, chemical materials, viscous 
liquid and suspended solids. It has low conductivity measurement 
function. 
Ex explosion-proof design meet the requirements of the national 
explosion-proof technology, it has passed the identification and 
acceptance, and it can be used in all kinds of explosion-proof 
places.
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Fast response design of high resistance can collect the weak signals without distortion and reflect the change of the flow. The range ratio can reach to 100:1. 
It used the empty and full pipe detection of capacitive technology and prevent the false alarm of emergence.
It has the consistency of the converter swap, It's no need to re-enter the parameters. 
And it has wide range power type to choose (DC: 18V~36V AC: 85V~265V). 
It uses the factory function to save the settings and to ensure that no danger of anything going wrong with the instrument parameters. 
Infrared remote control function and keys operation let the operation more convenient. 
It has the function of sensor zero correction and automatic zero calibration. 
Chinese (Engl ish) interface can meet different kinds of requirements. 
It also has converter self-calibration and self check function. 
The circuit has anti lightning protection design. Anti-interference circuit can apply to harsh environment.
It has digital communication signal output, like RS485, RS232, Hart, Modbus and Profibus,etc. 
Converters and sensors have a variety of protection levels and installation methods. IP68 level is suitable for diving installation. 
Inserted electromagnetic flowmeter in large pipe flow measurement has advantages, like simple installation, without interrupting scene and hot tapping, so it has installation advantage and price advantage. 
The measurement of the inserted electromagnetic flowmeter is only related to the depth of insertion, so the flowmeter is widely used and has high interchangeability. A kind of type can be applied to a variety 
of specifications of the pipeline fluid measurement.
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements

 

Technical Parameters
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Model TK1100 standard series TK1200 high accuracy series
Caliberl DN3-DN2200 DN10-DN300
Accuracy 0.5% 0.2%,0.3%
Installation method Hold,flange Hold,flange
Repeatability 0.1% 0.06%,0.1%
Measuring range 0-12m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 4.0MPa~0.25 Mpa
(classify by caliber)
4.0MPa~0.25 Mpa
(classify by caliber)
Lining material PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard,(scraper,it can be replaced by DN>350) Standard,(scraper,it can be replaced by DN>350)
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >2μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) Integrated type≤90ºC,split type≤160ºC(rubber)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode Integrated,split Integrated,split
Output  signal 4-20mA current signal,frequency /pulse output 4-20mA current signal,frequency/pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis yes yes
Zero setting of empty pipe yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards JB/T 9248-1999 JB/T 9248-1999
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Model TK1300 hygienic series TK1500 battery powered series
Caliberl DN3-DN150 DN10-DN1200
Accuracy 0.2%,0.5% 0.5%
Installation method Thread,clamp Hold,flange
Repeatability 0.06%,0.1% 0.15%
Measuring range 0-12m/s(flow unit can be changed) 0-10m/s(flow unit can be changed)
Connecting flange   GB/T9119-2000 or any other choice
Pressure The highest 4.0MPa 4.0MPa~0.6 Mpa
(classify by caliber)
Lining material PFA(negative pressure resistance) PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard,(scraper,it can be replaced by DN>350)
Protection leve of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >2μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode ntegrated,split Lntegrated,split
Output signal 4-20mA current signal,frequency/pulse output Frequency 0-5kHz
Power supply AC:85V~265V,DC:18V~36V 3.6V
Self diagnosis Yes Yes
Zero setting of empty pipe Yes Yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,GPRS
Explosion-proof No explosion proof/explosion proof  
Language Chinese,English Chinese,English
Product standards   JB/T 9248-1999
 
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Model TK1400 inserted type series TK1600 electromagneticheat meter series
Caliberl DN200-DN3000 DN15-DN1200
Accuracy 1.5%;2.5% 1.0%,2.0%,2.5%
Installation  method Flange,thread,on-line Hold,flange,thread
Repeatability 0.5% 0.3%;0.5%
Measuring range 0-10m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 1.6MPa 4.0MPa~0.6Mpa
(classify by caliber)
Lining material POM,PTFE,PFA PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode  material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC)
Ambient  maximum  temperature -30ºC~+65ºC -30ºC~+65ºC
Converter  installation  mode Integrated,split Integrated,split
Output signal 4-20mA  current  signal,frequency/pulse  output 4-20mA current signal,frequency /pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis Yes yes
Zero setting of empty pipe Yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards   Refer to 9248-1999 JB/T
Please contact us to obtain the datasheet.
Company Profile
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a beacon of excellence within the prestigious Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. group.
Founded in the dynamic city of Shanghai in 2013, Cold Valley is a proud affiliate of Hanshan Intelligent Technology Co., Ltd., distinguished for its industry leadership.
Our team of founding experts is drawn from top-tier international automation firms, boasting over two decades of cumulative experience in automation and engineering. With a decade's forte in consulting and digital solutions, we are committed to delivering unparalleled automation and digitization products and services from our Shanghai headquarters.
With a rich history of over 20 years in the industry, we excel in the petrochemical sector, possessing deep insights into the automation and digitalization needs of enterprises across all stages. We specialize in delivering bespoke products and solutions enhanced by automation and digitalization, as well as comprehensive life cycle services to industries such as petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements
Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements

Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate MeasurementsAdvanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate MeasurementsAdvanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate MeasurementsAdvanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate MeasurementsAdvanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements

Advanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate MeasurementsAdvanced Non-Intrusive Electromagnetic Flowmeter with Ai Technology for Accurate Measurements

Frequently Asked Questions

How to Choose the Right Product?
A: Once we receive your inquiry, we will promptly provide you with an extensive technical document, enabling you to closely evaluate vital process parameters and technical specifications. Based on your specific needs, we will recommend the most fitting model precisely tailored for you.

Desire a Confirmed Model?

A: Absolutely. Upon receiving your model specification, we will carefully verify its suitability, offering further cost-effective optimization suggestions if necessary. Once confirmed, we will proceed with a detailed formal quotation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier