Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Year of Establishment
2024-11-19
Plant Area
50 square meters
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
  • Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Find Similar Products
  • Overview
  • Technical Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang electromagnetic flowmeter
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

Harnessing cutting-edge international excitation technology, the
excitation circuit boasts simplicity, unwavering stability, and exceptional reliability, all while featuring
the prowess of artificial intelligence.
With no moving parts and no obstructions within the
pipeline, efficiency is maximized.
Experience zero additional pressure loss, ensuring that measurement results remain
unaffected by flow velocity distribution, fluid pressure,
temperature, density, viscosity, and other physical parameters.
Easily adjust the measurement range online to meet user-specific requirements.
Ideal for measuring the flow of conductive fluids such as tap
water, sewage, mud, various beverages, chemical materials, viscous
liquids, and even suspended solids. It also offers a low conductivity measurement
capability.
Our explosion-proof design adheres to national
explosion-proof standards, having successfully passed identification and
acceptance tests, allowing usage in a wide range of explosion-proof
environments.
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
With a fast-response high resistance design, it captures weak signals without distortion and accurately reflects flow changes, featuring an impressive range ratio of 100:1.
Utilizing capacitive technology for empty and full pipe detection, it prevents false alarms in critical scenarios.
Ensures consistency with interchangeable converters, eliminating the need for parameter re-entry.
Offers a versatile power supply range to suit various needs (DC: 18V~36V, AC: 85V~265V).
Factory settings safeguard against parameter misconfigurations, ensuring reliable performance at all times.
The infrared remote control and keypad make operation exceptionally convenient.
Equipped with sensor zero correction and automatic zero calibration functions.
The user interface, available in Chinese and English, caters to diverse requirements.
Additionally, it features converter self-calibration and self-check functions for enhanced reliability.
The circuit is designed with anti-lightning protection and anti-interference features to withstand harsh environments.
It supports a variety of digital communication outputs, including RS485, RS232, Hart, Modbus, and Profibus.
Converters and sensors come in various protection levels and installation methods, with IP68 suitable for submersible setups.
The inserted electromagnetic flowmeter excels in large pipe flow measurement, offering simple installation without disrupting operations, making it both cost-effective and efficient.
Flow measurement for the inserted electromagnetic flowmeter is purely reliant on the insertion depth, leading to wide usability and high interchangeability. One type accommodates multiple
pipeline fluid specifications, ensuring broad compatibility.
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features

 

Technical Parameters
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Model TK1100 standard series TK1200 high accuracy series
Caliberl DN3-DN2200 DN10-DN300
Accuracy 0.5% 0.2%,0.3%
Installation method Hold,flange Hold,flange
Repeatability 0.1% 0.06%,0.1%
Measuring range 0-12m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 4.0MPa~0.25 Mpa
(classify by caliber)
4.0MPa~0.25 Mpa
(classify by caliber)
Lining material PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard,(scraper,it can be replaced by DN>350) Standard,(scraper,it can be replaced by DN>350)
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >2μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) Integrated type≤90ºC,split type≤160ºC(rubber)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode Integrated,split Integrated,split
Output  signal 4-20mA current signal,frequency /pulse output 4-20mA current signal,frequency/pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis yes yes
Zero setting of empty pipe yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards JB/T 9248-1999 JB/T 9248-1999
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Model TK1300 hygienic series TK1500 battery powered series
Caliberl DN3-DN150 DN10-DN1200
Accuracy 0.2%,0.5% 0.5%
Installation method Thread,clamp Hold,flange
Repeatability 0.06%,0.1% 0.15%
Measuring range 0-12m/s(flow unit can be changed) 0-10m/s(flow unit can be changed)
Connecting flange   GB/T9119-2000 or any other choice
Pressure The highest 4.0MPa 4.0MPa~0.6 Mpa
(classify by caliber)
Lining material PFA(negative pressure resistance) PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard,(scraper,it can be replaced by DN>350)
Protection leve of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >2μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode ntegrated,split Lntegrated,split
Output signal 4-20mA current signal,frequency/pulse output Frequency 0-5kHz
Power supply AC:85V~265V,DC:18V~36V 3.6V
Self diagnosis Yes Yes
Zero setting of empty pipe Yes Yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,GPRS
Explosion-proof No explosion proof/explosion proof  
Language Chinese,English Chinese,English
Product standards   JB/T 9248-1999
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Model TK1400 inserted type series TK1600 electromagneticheat meter series
Caliberl DN200-DN3000 DN15-DN1200
Accuracy 1.5%;2.5% 1.0%,2.0%,2.5%
Installation  method Flange,thread,on-line Hold,flange,thread
Repeatability 0.5% 0.3%;0.5%
Measuring range 0-10m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 1.6MPa 4.0MPa~0.6Mpa
(classify by caliber)
Lining material POM,PTFE,PFA PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode  material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC)
Ambient  maximum  temperature -30ºC~+65ºC -30ºC~+65ºC
Converter  installation  mode Integrated,split Integrated,split
Output signal 4-20mA  current  signal,frequency/pulse  output 4-20mA current signal,frequency /pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis Yes yes
Zero setting of empty pipe Yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards   Refer to 9248-1999 JB/T
We invite you to reach out to us for the comprehensive datasheet that will provide detailed insights into our Highpeak Non-Intrusive Flowmeter, featuring state-of-the-art electromagnetic measurement capabilities.
Company Profile
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a beacon of excellence within the prestigious Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. group.
Founded in the dynamic city of Shanghai in 2013, Cold Valley is a proud affiliate of Hanshan Intelligent Technology Co., Ltd., distinguished for its industry leadership.
Our team of founding experts is drawn from top-tier international automation firms, boasting over two decades of cumulative experience in automation and engineering. With a decade's forte in consulting and digital solutions, we are committed to delivering unparalleled automation and digitization products and services from our Shanghai headquarters.
With a rich history of over 20 years in the industry, we excel in the petrochemical sector, possessing deep insights into the automation and digitalization needs of enterprises across all stages. We specialize in delivering bespoke products and solutions enhanced by automation and digitalization, as well as comprehensive life cycle services to industries such as petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features
Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features

Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement FeaturesHighpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement FeaturesHighpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement FeaturesHighpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement FeaturesHighpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features

Highpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement FeaturesHighpeak Non-Intrusive Flowmeter with Advanced Electromagnetic Measurement Features

Frequently Asked Questions

How to Choose the Right Product?
A: Once we receive your inquiry, we will promptly provide you with an extensive technical document, enabling you to closely evaluate vital process parameters and technical specifications. Based on your specific needs, we will recommend the most fitting model precisely tailored for you.

Desire a Confirmed Model?

A: Absolutely. Upon receiving your model specification, we will carefully verify its suitability, offering further cost-effective optimization suggestions if necessary. Once confirmed, we will proceed with a detailed formal quotation.

Send your message to this supplier