Customization: | Available |
---|---|
Accuracy: | 0.2%-1.0% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas |
Suppliers with verified business licenses
The MF2 Series Intelligent Electromagnetic Flowmeter is a masterpiece of precision, crafted using cutting-edge international manufacturing techniques. This remarkable instrument features a dual-language display in both Chinese and English, empowering users with choice and flexibility. With both low-frequency and high-frequency excitation options available, this flowmeter excels in the accurate measurement of slurry and other conductive liquids. Its exceptional attributes include high precision, energy efficiency, and ease of maintenance, making it an indispensable tool across a multitude of industries. From metallurgy to urban development, chemical processing to environmental management, and food production to pharmaceuticals, this flowmeter measures the volume flow of conductive liquids, including raw sewage, ore pulp, and acid-base solutions, with unwavering accuracy and reliability.
Model | MF20 flange-mounted | MF21 clip-on | MF22 sanitary | MF23/24 insertion |
Diameter | DN10~DN1200 | DN10~DN200 | DN10~DN100 | DN80~DN2000 |
Lining Material |
PTFE, FEP, PFA, neoprene rubber, polyurethane rubber | PTFE,FEP,PFA |
PTFE |
|
Electrode Material | 316L,Hb,Hc,Ti,Ta,platinum, etc. | |||
Medium Conductivity | >5μS/cm | |||
Accuracy | Class 0.2, Class 0.5, Class 1.0 | Class 1.0, Class 2 | ||
Flow Rate Range | 0.3 m/s~12m/s | 1 m/s~10m/s | ||
Medium Temperature |
PTFE(-80~+180ºC), FEP(-50~+150ºC), PFA(-50~+180ºC) Neoprene rubber(-45~+80ºC), Polyurethane rubber(-30~+70ºC) | |||
Environmental Temperature Standard | -40~+80ºC (LCD display environmental temperature -20ºC ~ +70ºC, exceeding this temperature will not cause damage) Explosion-proof: -20~+60ºC | |||
Working Pressure | 0.6MPa~42MPa / 150LB~2500LB or customized as per user requirements | 6.3MPa / 300LB | ||
Applicable Power Supply | 85~250V AC,20~36V DC | |||
Power Consumption | < 20W | |||
Protection Level | IP65,IP67,IP68 | |||
Output Signal Current | 0~10mA or 4~20mA, Frequency/Pulse: 1~5000Hz | |||
Communication Interface | RS485 or HART | |||
Applications |
Water industry, chemical industry, steel mills, power plants, etc. | Food processing and pharmaceutical industries, etc. | Water industry, steel mills, etc. |
|
Connection Form | Flange installation | sanitary installation | insertion installation | |
Sensor Structure | One-piece, split type | |||
Explosion-proof Mark | Ex ia/de IIC T3/T4 Ga/Gb | |||
Electrical Interface | M20×1.5(F), 1/2"NPT(F) or customized as per user requirements | |||
Optional Accessories | Equipped as per user requirements |
Flange type Integrated Split Type
Clamp-on type Integrated Split Type
Sanitary type Integrated Split Type