P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter

Product Details
Customization: Available
Accuracy: 0.15%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (10)
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
  • P 50 Coriolis Flow Meter P Series Precise Mass Flow & Density Meter
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Size
DN6-80
Sensor
Tube/Flange
Application
Environmental Protection
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measurement Object
Closed Pipeline
Certification
CE
Process Temperature
-100~180°c
Ambient Temperature
-40~60°c
Range
0.67~885nm3/H
Flange Standard
ANSI
Flange Material
316L
Flange Size
ANSI 2"150RF
Body Material
Aluminum
Element Material
316L
Mounting Style
Integral
Power Supper
24VDC
Output Signal
4-20mA
Output Indicator
Yes
Electrica Connect
1/2"NPT
Explosion Proof
Ex Ia Iict4
Pressure
0-50bar
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
100000peices/Years

Product Description

P Series Precise Mass Flow & Density Meter
. Applied to Liquid, Gas, Slurry Mass Flow
. Mass Flow Accuracy ±0. 1%(Liquid),±0.5%(Gas) . Density Measuring Accuracy ±1kg/m3
. Normal Diameter DN10~DN250
. Process Temperature Ranges -40ºC~+350ºC
Component Parts of P Series Coriolis Mass Flow Meter
P Series Coriolis Mass Flow Meter is defined as P series Mass Flow Meter with flow accuracy is 0. 1%, whom is made ofP series mass flow Sensor and DPT100 Transmitter.

Features and Benefits of P Series Coriolis Mass Flow Meter
l Double U or double C type flow pipe design is better for measuring accuracy
l Provides integrated mass flow, volume flow, density, temperature measurement and the calculates the others relevant parameters
l Easy on installation, no need rectifier, filter parts, no special requirements for installing direct pipe section
l Without  moving  parts  and  no  need  frequent  maintain;  high  stable  function  no  need  frequent calibration
l Allows low range flow running, reducing pressure loss to keep high efficiency
l Compact installation to save installation costs
l Being compatible with N series A(flanges faces interval distance) dimension
l Ultra precision measuring and long term stability functions for custody transfer measurement
l Ultra wide turndown ratio for gas measuring
l The connected Transmitter can be exchanged for easy maintain
l No being influenced by ambient temperature
 
Liquid Flow Rate Performance Index                                                                           

 
    Mass flow rate Volume flow rate[1]
    Kg/h L/h
Maximum mass P10 1500 1500
flow rate P15 4500 4500
  P20 9450 9450
  P25 25500 25500
  P50 94500 94500
  P80 240000 240000
  P100 540000 540000
  P150 825000 825000
  P200 1650000 1650000
  P250 2700000 2700000

Mass flow accuracy[2]       15:1 within turndown[3] ±0. 1%
15:1 beyond turndown ±(zero stability/instant rate)×100%


Volume flow accuracy[2]       FS      ±0. 15±(Zero Stability / Instant Flow Rate) × 100%


 
Repeatability 15:1 within turndown ±0.05%
  15:1 beyond turndown ±1/2(Zero Stability / Instant Flow Rate)×100%

Kg/h
 
 
Zero Stability

P10   P15   P20   P25   P50   P80   P100 P150 P200 P250

0.10   0.30   0.63   1.70   6.30   16.0   36.0   55.0   110.0 180.0

[1]The  criterion  of volume  flow rate  is  as per  density. Regarding to the process  liquid  density  isn't 1000kg/m3, the value of volume flow is value of maximum mass flow divided by liquid density.
[2]Flow Accuracy includes repeatability, linearity and hysteresis.
[3]Turndown is defined as the value of maximum flow divided by minimum flow.

Accuracy, Turndown and Pressure Loss of P50 connected with DPT100 Transmitter
Turndown (from the maximum flow) 20:1 15:1 5:1 1.5:1 1:1
Accuracy  ±% 0. 14 0. 1 0. 1 0. 1 0. 1
Pressure Drop MPa 0.001 0.002 0.02 0. 1 0.23

Note:when the maximum flow rate exceeds the given flow rate range, the noise from the pipe will affect the accuracy.



Gas Measurement Performance
Mass flow accuracy    (flow rate > zero stability/0.005)     ±0.5%
(flow rate < zero stability/0.005)     ±(zero stability/instant flow rate)x100% Mass flow repeatability    (flow rate>zero stability/0.005)       ±0.25%
(flow rate<zero stability/0.005)      ±1/2(zero stability/instant flow rate)x100%

Standard Volume
In most application areas, customers are used to use standard volume to determine the volume under pressure  and  temperature,  standard  volume  also  called  as  "standard  mass"  flow  unit  to  the  fixed component liquid. Applied to the density under standard condition(receiving from reference data), flow meter would be  output under the  configuration  of standard volume unit,which  means that  could be calculated  between  measured  liquid  quality  and  entrained  liquid  standard  density,  but  no  need  the compensation of pressure, temperature and density. For more information pls. contact your local agency.


Pressure Loss
pressure loss is affected by the sensor geometric form, gas density and flow rate. While customers are suggested that the sensor pressure loss couldn't surpass 0. 127Mpa when design type selection.


Flow Rate
The flow rate of gas measure is much greater than the flow rate of liquid measure, the higher flow rate leads to the noise will affect the signal of flow meter. So the flow rate within sensor pipe should be lower 0.5 times than sounds rate when the pressure loss of flow meter under 0. 127Mpa.

 
P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter

Model Selection Principle
l In the applied fields of Coriolis Mass Flow Meter, the Max. Flow rate is decided by pressure loss while the Min. Flow rate is decided by measuring accuracy
l Before selecting the product, the client or user should firstly refer to this manual, using the size selection software provided by Xi'an Dongfeng Machinery & Electronic Co., Ltd., as well as the user should provide the relevant data such as accuracy, flow rate, pressure loss, density, viscosity, temperature, etc., which  ensures the  correct  size  selection and application. The  software  can be obtained   from    salespersons   of   the    agency   or    downloaded   from    the   company
 

P50 Compact Installation
P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterNote:The Listed Flanges In The Below Tables Are Welding-neck Steel Pipe Flanges RF
 
Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D

F
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 922 201 18 125 165 180
65(Optional) 4.0 570 460 595 702 922 201 18 145 185 180
 
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D

F
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 922 201 18 127 165 180
65(Optional) 300 620 460 595 702 922 201 22 149.2 190 180
  


P50 Remote InstallationP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter

Note:The Listed Flanges In The Below Tables Are Welding-neck Steel Pipe Flanges RF
 

Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 845 201 18 125 165
65(Optional) 4.0 570 460 595 702 845 201 18 145 185
 
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 845 201 18 127 165
65(Optional) 300 620 460 595 702 845 201 22 149.2 190

 

Company Profile
P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a distinguished pillar within the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., epitomizing a commitment to unparalleled innovation and excellence.
(hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) officially embarked on its journey in the vibrant cityscape of Shanghai in 2013, heralding a transformative era of technological progress.
The founding team, a cadre of industry veterans from the world's foremost automation leaders, brings an extraordinary wealth of experience: over 20 years in the automation sector, in addition to two decades in automation engineering, and 10 years in pioneering digital solutions. Their mission is unequivocal: to deliver premier automation and digitization products and services to clients worldwide. Based strategically in Shanghai, China, the company is a shining icon of technological expertise.
Boasting an impressive legacy exceeding two decades in the petrochemical realm, the company holds unmatched insights into the automation and digitalization needs across the entire industry spectrum-upstream, midstream, and downstream. They offer a suite of professional-grade products and comprehensive solutions, meticulously crafted for industries such as petroleum, chemical, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, guaranteeing excellence throughout the product lifecycle.
P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter
P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter

P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter

P 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density MeterP 50 Coriolis Flow Meter P Series Precise Mass Flow &amp; Density Meter

You may have these questions

How do I select the right product?
A: Upon receiving your inquiry, our extensive technical dossier will furnish all the essential insights you require. This documentation empowers you to thoroughly examine the process parameters and technical specifications pertinent to your needs. Armed with this information, we will expertly recommend the model that aligns impeccably with your precise requirements.

I would like a confirmed model. Can you provide that?
A: Absolutely. Once you express interest in a particular model, we will undertake a meticulous verification process to ensure its suitability. Should there be opportunities for cost-effective enhancements, we will readily propose optimization suggestions. Upon your confirmation, we will proceed to craft a formal quotation, meticulously tailored to meet your objectives.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier