Basic accuracy: Impeccably precise at ±0.04%, with a top-tier maximum of ±0.025%, ensuring the highest standards of measurement reliability.
Range ratio: Offers an expansive 100:1 range, providing exceptional versatility for diverse applications.
Response time: Swift and efficient with a 90ms response time and a rapid 50ms data refresh, ensuring prompt and reliable data updates.
Range range: Differential pressure from an impressive 0-100 Pa up to 14MPa, accommodating a wide spectrum of measurement needs.
Pressure of 0-1 kPa-70MPa: Exceptionally broad pressure capabilities, managing extensive pressure ranges effortlessly.
Output signal: Delivers a dynamic 4-20 mA signal, enhanced with HART protocol communication, compatible with both HART6.0 and HART 7.0 versions, for seamless integration.
PROFIBUS-PA fieldbus communication: Utilizes version 3.02 for robust and efficient fieldbus communication capabilities.
FF Fidbus Communication: Incorporates Version 6.1.1, providing thorough and reliable communication for field operations.
Overload limit: Handles differential pressure up to an impressive 42MPa, offering exceptional overload protection.
Pressure of 105MPa: Capable of managing pressures up to 105MPa, ensuring resilience and reliability under high-pressure conditions.
Effect of the static pressure: Maintains precision with a minimal effect of 0.03%FS at 16MPa, ensuring accuracy under static pressure conditions.
Temperature range: Operates in ambient temperatures of -40ºC to 80ºC, with specific considerations for explosion-proof environments.
Process temperature: Efficiently manages process temperatures ranging from -90ºC to an impressive 700ºC.
LCD temperature: Reliable performance between -35ºC and 80ºC, catering to diverse environmental needs.
Long-term drift: Exhibits exceptional stability with ± 0.1%FS drift over an impressive 10 years.
Temperature Effect: Offers a minimal effect of (0.06 * r + 0.01)% over 28ºC within the range of -40ºC to 80ºC.
Explosion-proof grade: NEPSI certified for Type Ex iaIICT4 Ga, suitable for ambient temperatures from -40ºC to 60ºC (Note 1).
NEPSI: Certified for Intrinsic Ex iaIICT6 Ga, ideal for environments with ambient temperatures from -40ºC to 40ºC (Note 1).
NEPSI: Explosion-proof type Ex dIICT6 Gb, applicable for ambient temperatures from -40ºC to 60ºC, ensuring safety in volatile conditions.
NEPSI: Dust explosion protection with Ex tD A21 IP67 T85ºC, safeguarding against dust-related hazards.
NEPSI: 'n' explosion-proof Ex nACT6 Gc, suitable for ambient temperatures from -40ºC to +60ºC, ensuring safety in challenging environments.
ATEX: Certified for Ben Ex II 1 G Ex iaIICT4 Ga, providing intrinsic safety and reliability.
ATEX: Bursting with safety features, certified for Ex II 1 / 2 G Ex dbIICT6-T 4 Ga / Gb, ensuring robust protection.
IECEx: Intrinsic safety certified for Ex iaIICT4 Ga, offering reliable safety features for global compliance.
IECEx: Certified for burst protection with Ex dbIICT6-T 4 Ga / Gb, ensuring comprehensive safety measures.