Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Year of Establishment
2024-11-19
Plant Area
50 square meters
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
  • Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Find Similar Products
  • Overview
  • Technical Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang electromagnetic flowmeter
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

It uses the international leading excitation technology. The
excitation circuit is simple, stable and reliable, it has the
performance of artificial intelligence.
There are no movable parts and no resisting flow parts in the
pipeline.
There is no additional pressure-loss. The measurement results
have no relationship to flow velocity distribution, fluid pressure,
temperature, density, viscosity and other physical parameters.
It can modify the range online according to the actual need of users .
It can be used to measure the flow of conductive fluid,such as tap
water, sewage, mud, all kinds of drinks, chemical materials, viscous
liquid and suspended solids. It has low conductivity measurement
function.
Ex explosion-proof design meet the requirements of the national
explosion-proof technology, it has passed the identification and
acceptance, and it can be used in all kinds of explosion-proof
places.
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Fast response design of high resistance can collect the weak signals without distortion and reflect the change of the flow. The range ratio can reach to 100:1.
It used the empty and full pipe detection of capacitive technology and prevent the false alarm of emergence.
It has the consistency of the converter swap, It's no need to re-enter the parameters.
And it has wide range power type to choose (DC: 18V~36V AC: 85V~265V).
It uses the factory function to save the settings and to ensure that no danger of anything going wrong with the instrument parameters.
Infrared remote control function and keys operation let the operation more convenient.
It has the function of sensor zero correction and automatic zero calibration.
Chinese (Engl ish) interface can meet different kinds of requirements.
It also has converter self-calibration and self check function.
The circuit has anti lightning protection design. Anti-interference circuit can apply to harsh environment.
It has digital communication signal output, like RS485, RS232, Hart, Modbus and Profibus,etc.
Converters and sensors have a variety of protection levels and installation methods. IP68 level is suitable for diving installation.
Inserted electromagnetic flowmeter in large pipe flow measurement has advantages, like simple installation, without interrupting scene and hot tapping, so it has installation advantage and price advantage.
The measurement of the inserted electromagnetic flowmeter is only related to the depth of insertion, so the flowmeter is widely used and has high interchangeability. A kind of type can be applied to a variety
of specifications of the pipeline fluid measurement.
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology

 

Technical Parameters
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Model TK1100 standard series TK1200 high accuracy series
Caliberl DN3-DN2200 DN10-DN300
Accuracy 0.5% 0.2%,0.3%
Installation method Hold,flange Hold,flange
Repeatability 0.1% 0.06%,0.1%
Measuring range 0-12m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 4.0MPa~0.25 Mpa
(classify by caliber)
4.0MPa~0.25 Mpa
(classify by caliber)
Lining material PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard,(scraper,it can be replaced by DN>350) Standard,(scraper,it can be replaced by DN>350)
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >2μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) Integrated type≤90ºC,split type≤160ºC(rubber)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode Integrated,split Integrated,split
Output  signal 4-20mA current signal,frequency /pulse output 4-20mA current signal,frequency/pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis yes yes
Zero setting of empty pipe yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards JB/T 9248-1999 JB/T 9248-1999
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Model TK1300 hygienic series TK1500 battery powered series
Caliberl DN3-DN150 DN10-DN1200
Accuracy 0.2%,0.5% 0.5%
Installation method Thread,clamp Hold,flange
Repeatability 0.06%,0.1% 0.15%
Measuring range 0-12m/s(flow unit can be changed) 0-10m/s(flow unit can be changed)
Connecting flange   GB/T9119-2000 or any other choice
Pressure The highest 4.0MPa 4.0MPa~0.6 Mpa
(classify by caliber)
Lining material PFA(negative pressure resistance) PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard,(scraper,it can be replaced by DN>350)
Protection leve of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >2μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode ntegrated,split Lntegrated,split
Output signal 4-20mA current signal,frequency/pulse output Frequency 0-5kHz
Power supply AC:85V~265V,DC:18V~36V 3.6V
Self diagnosis Yes Yes
Zero setting of empty pipe Yes Yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,GPRS
Explosion-proof No explosion proof/explosion proof  
Language Chinese,English Chinese,English
Product standards   JB/T 9248-1999
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Model TK1400 inserted type series TK1600 electromagneticheat meter series
Caliberl DN200-DN3000 DN15-DN1200
Accuracy 1.5%;2.5% 1.0%,2.0%,2.5%
Installation  method Flange,thread,on-line Hold,flange,thread
Repeatability 0.5% 0.3%;0.5%
Measuring range 0-10m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 1.6MPa 4.0MPa~0.6Mpa
(classify by caliber)
Lining material POM,PTFE,PFA PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode  material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC)
Ambient  maximum  temperature -30ºC~+65ºC -30ºC~+65ºC
Converter  installation  mode Integrated,split Integrated,split
Output signal 4-20mA  current  signal,frequency/pulse  output 4-20mA current signal,frequency /pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis Yes yes
Zero setting of empty pipe Yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards   Refer to 9248-1999 JB/T
Delve deeper into our technology by reaching out to us for a comprehensive datasheet that unveils the intricate details and specifications, ensuring you grasp the full potential of our product.
Company Profile
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. is a shining testament to distinguished excellence within the renowned Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. family.
Nestled in the vibrant metropolis of Shanghai since 2013, Cold Valley proudly operates as an esteemed affiliate of Hanshan Intelligent Technology Co., Ltd., celebrated for its pioneering leadership and innovation.
Our founding team comprises top-tier experts sourced from leading international automation enterprises, collectively amassing over 20 years of rich expertise in automation and engineering. With a decade dedicated to consulting and groundbreaking digital solutions, we are steadfast in our mission to provide unparalleled automation and digitization innovations from our dynamic Shanghai hub.
Boasting a legacy of over two decades in the industry, we are leaders in the petrochemical field, offering profound insights into the automation and digitalization demands of enterprises at every phase. We excel in crafting bespoke, cutting-edge products and solutions enhanced by automation and digital finesse, while delivering comprehensive life cycle services to a diverse range of industries including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology
Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology

Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement TechnologyAccurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement TechnologyAccurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement TechnologyAccurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement TechnologyAccurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology

Accurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement TechnologyAccurate Electromagnetic Flowmeter Featuring Advanced Ai Measurement Technology

Frequently Asked Questions

How to Choose the Right Product?
A: Upon receiving your inquiry, we will swiftly furnish you with a comprehensive technical document, allowing you to meticulously assess crucial process parameters and technical specifications. Tailoring our recommendations to your unique requirements, we will suggest the most ideal model, precision-crafted to suit your needs.

Desire a Confirmed Model?

A: Absolutely. Once we receive your model specification, we will thoroughly verify its compatibility, providing further cost-saving optimization advice if needed. Upon confirmation, we will advance with a detailed and formal quotation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier