Basic accuracy: Achieve unparalleled precision with PDS800's basic accuracy of ±0.04%, reaching an exceptional maximum of ±0.025%. This ensures that every measurement you take is delivered with the utmost accuracy, elevating your operational excellence.
Range ratio: Unleash the potential of adaptability with a remarkable 100:1 range ratio. This feature offers our users an expansive scope to effortlessly tackle diverse pressure ranges with superior accuracy and ease.
Response time: Experience lightning-fast response times as quick as 90ms, with a dynamic data refresh rate of 50ms. This ensures you receive timely, accurate pressure readings, empowering your operations with speed and reliability.
Range range: Discover incredible versatility with the capability to measure differential pressure from 0-100 Pa to a staggering 14MPa. The PDS800 is engineered to provide a comprehensive range of pressure measurements, adapting to varied conditions seamlessly.
Pressure of 0-1 kPa-70MPa: Effortlessly handle a vast range of pressures from 0-1 kPa to an impressive 70MPa. This ensures that PDS800 is versatile across multiple applications, catering to various industry needs with precision.
Output signal: Benefit from a robust 4-20 mA signal coupled with advanced HART protocol communication. This ensures compatibility with both HART6.0 and HART7.0 versions, offering a reliable and efficient communication framework for your systems.
PROFIBUS-PA fieldbus communication: Achieve seamless integration with version 3.02 for optimized communication capabilities. This feature ensures you maintain industrial excellence through superior connectivity and operational efficiency.
FF Fidbus Communication: Ensure efficient data exchange and system integration with compatibility for Version 6.1.1. Leverage this feature for robust system communication and enhanced operational coordination.
Overload limit: Withstand the rigors of high-pressure environments with an impressive differential pressure capacity of 42MPa. This capability ensures durability, enhancing the safety and longevity of your operations.
Pressure of 105MPa: Stand strong in challenging environments with the ability to endure pressures up to an immense 105MPa. This reinforces the PDS800's robustness and reliability under extreme conditions, safeguarding your processes.
Effect of the static pressure: Maintain consistent accuracy with minimal static pressure impact of just 0.03%FS at 16MPa. This ensures reliable performance under static conditions, preserving measurement integrity.
Temperature range: Thrive in diverse environments with a functioning range from -40ºC to 80ºC. With specific explosion-proof considerations, the PDS800 is engineered for exceptional performance across temperature extremes.
Process temperature: Operate with confidence in process temperatures spanning from -90ºC to a remarkable 700ºC. This feature showcases the PDS800's superior high-temperature performance, empowering you to handle extreme conditions effortlessly.
LCD temperature: Maintain visibility and functionality with the ability to withstand LCD temperatures from -35ºC to 80ºC. This ensures continued performance across diverse conditions, enhancing operational reliability.
Long-term drift: Ensure sustained accuracy with minimal drift of ±0.1%FS over an impressive 10-year period. This long-term reliability guarantees that your operations remain precise and dependable over time.
Temperature Effect: Rely on precision with a temperature effect of (0.06 * r + 0.01)% per 28ºC, maintaining functionality between -40ºC and 80ºC. This ensures your operations are backed by reliable and consistent performance.
Explosion-proof grade: NEPSI certified for Type Ex iaIICT4 Ga, the PDS800 stands as a beacon of safety for ambient temperatures from -40ºC to 60ºC. This ensures secure operations in volatile environments, safeguarding your processes.
NEPSI: Experience intrinsic safety with Ex iaIICT6 Ga certification, functional from -40ºC to 40ºC. This offers unwavering protection in explosive environments, ensuring your peace of mind.
NEPSI: Benefit from explosive protection with Ex dIICT6 Gb, operational between -40ºC and 60ºC. This ensures robust safety measures are in place, amplifying secure usage in high-risk scenarios.
NEPSI: Secure protection against dust explosions with Ex tD A21 IP67 T85ºC. This ensures reliable safety measures are upheld in challenging dust-prone conditions.
NEPSI: Utilize 'n' explosion-proof Ex nACT6 Gc for safe operation from -40ºC to +60ºC. This ensures safety and reliability in potentially explosive atmospheres, providing you with secure operations.
ATEX: Attain top-tier safety certification with Ben Ex II 1 G Ex iaIICT4 Ga. This ensures the highest standards of safety are met in hazardous environments, protecting your operations.
ATEX: Experience exceptional protection with Burst Ex II 1 / 2 G Ex dbIICT6-T 4 Ga / Gb. This ensures unparalleled safety in explosive and high-pressure conditions, fortifying your operational security.
IECEx: Embrace global safety standards with Intrinsic safety Ex iaIICT4 Ga. This ensures your operations are safeguarded with reliable intrinsic safety features, adhering to international safety norms.
84d3e8fb