Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement

Product Details
Customization: Available
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Year of Establishment
2024-11-19
Plant Area
50 square meters
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
  • Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Find Similar Products
  • Overview
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang turbine flowmeter
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

 
Product Parameters
 
TK5100 Turbine Flow Meter
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Medium Measured Liquid without impurity,low viscosity,no strong corrosive action
Standards Executed Turbine flow sensor(JB/T9246-1999)
Calibration Specification Turbine flow meter(JJG1037-2008)
Instrument Caliber Flange connection type DN15-DN200
Thread connection type DN4-DN50
Clamping connection type DN4-DN200
Instrument Material 304 stainless steel,316(L)stainless steel,etc.
Flange Standard Conventional standards GB/T9113-2000
Other standards International flange
standards
Like German standard DIN,American standard ANSI,
Japanese standard JIS
Domestic pipe flange
standards
Like standards of Ministry of Chemical Industry,
Standards of Ministry of Machinery
Thread Specifications Conventional specifications Pipe thread of British system (external thread)
Other specifications Internal thread,spherical thread,NPT thread,etc.
Accuracy Class and
Corresponding
Repeatability

Accuracy class*1
±0.1%R ±0.5%R ±0.2%R(has to be
    customized)
Repeatability ≤0.15% ≤0.1% ≤0.03%
Range ratio 10:1~20:1
Output signal  Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
 Transmitter:two-wire system4~20mADC current signal
Power supply  Sensor:+12VDC,+24VDC(optional)
 Transmitter:+24VDC\220V
 Display type on site:3.6V lithium battery on the instrument
Signal Transmission Line STVPV3×0.3(three-wire system),2×0.3(two-wire system)
Transmission Distance ≤1000m
Signal Line Interface Basic type:Hausman joint,explosion-proof type:internal thread M20×1.5
Explosion Proof Class Basic type:not explosion proof,explosion-proof type:ExdlIBT6
Calibration Conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid flow calibration device with static mass approach
Environmental conditions Ambient temperature 20ºC
Relative humidity 65%
Operation Conditions
Medium temperature
T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC

Ambient temperature
Atmospheric pressure
-20ºC~+70ºC Relative humidity 5%~90%
86kPa~106kPa
TK5200 Series Plug-In Liquid Turbine Flow Meter
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Measured Medium Large pipeline liquid like circulation water
Accuracy Class ±5%,±2.5%
Sensor Type Tangential type
Axial sensor
Structure Type  Integrated meter
Split type meter
Instrument Caliber and
Connection Type
Easy plug-in DN150-DN1100
Online plug-in DN150-DN1100
Pressure Class 1.6MPa
Meter Material Screw Stainless steel Impeller 2Cr13
  Flange Carbon steel Guide frame Stainless steel
Short section Ball valve
Plug-in type depth When the inner diameter of the pipeline (DN)≤1050mm,the plug-in depth is:
Tangential type 0.5×DN-20mm
Axial type 0.5×DN
Range ratio 10:1
Output signal Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
Transmitter:two-wire system 4~20mADC current signal
Power supply Sensor:+12VDC,+24VDC(optional)
Transmitter:+24VDC,220V
On-site display type:3.6V lithium battery on the instrument
Signal transmission line STVPV3×0.3(three-wire system),2×0.3 (two-wire system)
Transmission distance ≤1000m
Signal line connection port Basic type:Hausman joint,explosion proof:inner thread M20×1.5
Explosion proof class Basic type:not explosion proof,explosion proof:ExdIIBT6
Calibration conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid fow calibration device with static mass approach
Ambient conditions Ambient temperature 20ºC
Relative humidity 65%
Operation conditions  Medium temperature T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC
Ambient temperature -20ºC~+70ºC    Relative humidity 5%~90%
atmospheric    pressure 86kPa~106kPa
TK5300 Series Sanitary Liquid Turbine Flow Meter
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Measurement medium Liquid for health care fields like food and liquor
Execution standards Turbine flow sensor(JB/T9246-1999)
Execution standards Turbine flow meter(JJG1037-2008)
Meter caliber and
connection method
Clamp connection type DN4-DN100
Accuracy class ±1%R,±0.5%R,±0.2%R
(to be made specially)
Instrument material Sensor 316(L)/304 stainless steel Guide frame 316/304
Impeller Dual phase steel 304
Range ratio 10:1~20:1
Pressure level 1.0MPa
Output signal Sensor:pulse frequency signal,low level≤0.8V,high level≥8V
Transmitter:two-wire system 4~20mADC current signal
Power supply Sensor:+12VDC,+24VDC(optional)
 Transmitter:+24VDC\220V
 On-site display type:3.6V lithium battery on the instrument
Signal transmission line STVPV3×0.3 (three-wire system),2×0.3(two-wire system)
Transmission distance ≤1000m
Signal line connection port Basic type:Hausman joint,explosion proof:inner thread M20×1.5
Explosion proof class
Basic type:not explosion proof,explosion proof:ExdlIBT6
Calibration conditions Calibration device Fluid flow calibration device with standard meter approach
Fluid flow calibration device with static mass approach
Ambient conditions Ambient temperature 20ºC
Relative humidity 65%
Operation Conditions Medium temperature T1(general type) -20ºC~+80ºC
T2(high temperature
type,optional)
-20ºC~+120ºC
T3(high temperature
type,optional)
-20ºC~+150ºC
Ambient temperature -20ºC~+60ºC Relative humidity 5%~90%
Atmospheric pressure 86kPa~106kPa
Company Profile
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. is a beacon of innovation, representing the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. As a trailblazer in the industry, our innovation and dedication establish a prestigious standard, soaring to new pinnacles of excellence.
Founded in the dynamic city of Shanghai in 2013, Cold Valley thrives as a valued arm of Hanshan Intelligent Technology Co., Ltd. Known for our commitment to innovation, we lead the industry with unmatched excellence, standing as a paragon of cutting-edge advancements.
Our elite team consists of seasoned professionals from top-tier international automation companies, collectively bringing over 20 years of rich automation and engineering experience. With a decade of specialization in consulting and digital solutions, we are passionately committed to delivering exceptional automation and digitalization products and services from our advanced Shanghai hub.
With a proud legacy spanning over two decades, we have expertly carved out a distinctive place in the petrochemical sector. Our comprehensive understanding of automation and digital needs at all business stages allows us to customize solutions with precision. Harnessing innovative automation and digitalization technologies, we deliver inclusive life cycle services across diverse industries such as petroleum, chemicals, power, biomedicine, APIs, food and beverage, alcohol, metallurgy, and non-ferrous metals.
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement
Durable Long-Term Stability Meter for Consistent Turbine Flow Measurement

Durable Long-Term Stability Meter for Consistent Turbine Flow MeasurementDurable Long-Term Stability Meter for Consistent Turbine Flow MeasurementDurable Long-Term Stability Meter for Consistent Turbine Flow MeasurementDurable Long-Term Stability Meter for Consistent Turbine Flow MeasurementDurable Long-Term Stability Meter for Consistent Turbine Flow Measurement

Durable Long-Term Stability Meter for Consistent Turbine Flow MeasurementDurable Long-Term Stability Meter for Consistent Turbine Flow Measurement

Frequently Asked Questions

How to Choose the Right Product?
A: When you reach out to us with an inquiry, we swiftly provide a comprehensive technical document, allowing you to meticulously assess key process parameters and technical specifications. In line with your distinct needs, we recommend the ideal model, perfectly tailored for precision and reliability.

Desire a Confirmed Model?

A: Certainly. Provide us with your model specifications, and we will rigorously verify its appropriateness, offering additional cost-saving optimization suggestions as needed. Upon your confirmation, we prepare a detailed and bespoke formal quotation just for you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier