Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Year of Establishment
2024-11-19
Plant Area
50 square meters
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
  • Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Find Similar Products
  • Overview
  • Technical Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Tiankang electromagnetic flowmeter
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Transport Package
Wooden
Trademark
Highpeak
Origin
China
HS Code
9026100000
Production Capacity
50000peices/Years

Product Description

The Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology leverages cutting-edge, world-class excitation technology.
Its simple, stable, and reliable excitation circuit exemplifies superior engineering design.
Boasting artificial intelligence capabilities, it elevates performance to new heights.
Ingeniously designed without any moving parts or flow-resisting components within the pipeline,
it ensures seamless and unobstructed flow measurement.
The device operates with zero additional pressure loss, offering precise results.
The accuracy remains unaffected by factors such as flow velocity distribution, fluid pressure,
temperature, density, viscosity, and other physical attributes, ensuring unparalleled consistency.
It offers the flexibility of online range modifications tailored to user-specific requirements.
Ideal for measuring diverse conductive fluids, it effortlessly handles tap water, sewage, mud,
various beverages, chemical substances, viscous liquids, and even suspended solids. It also features a low conductivity measurement capability.
This extraordinary capability ensures comprehensive fluid analysis and versatility.
Expertly designed for explosion-proof environments, it meets stringent national standards,
ensuring safe and reliable operation in explosive-prone settings, backed by rigorous identification and acceptance testing.
Its rapid-response high-resistance framework captures faint signals without distortion,
providing real-time reflections of flow changes, with an impressive range ratio of up to 100:1.
Innovative capacitive technology enables precise empty and full pipe detection, eliminating false alarms.
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Seamless converter swaps maintain parameter consistency, freeing users from reconfiguration hassles.
The device offers versatile power options, accommodating a wide range of supply voltages (DC: 18V~36V AC: 85V~265V).
Factory settings function ensures parameter safety and reliability, mitigating risks of operational mishaps.
User-friendly operation is enhanced by infrared remote control and manual key inputs, making interaction a breeze.
Featuring automatic zero calibration and sensor zero correction, it guarantees top-notch accuracy.
Supporting both Chinese and English interfaces, it caters to a broad spectrum of user preferences.
With self-calibration and self-check features for the converter, maintenance is straightforward and efficient.
Equipped with an anti-lightning protection circuit, it withstands harsh environmental conditions.
Digital communication options (RS485, RS232, Hart, Modbus, Profibus) ensure seamless data integration.
The flexible design offers multiple protection levels and installation methods, with IP68 rated for underwater use.
The inserted electromagnetic flowmeter simplifies large pipe flow measurements with easy installation,
offering substantial cost advantages by supporting hot tapping without site interruption.
Its measurement precision is solely influenced by insertion depth, facilitating wide usage and high interchangeability. A single type is compatible with various
pipeline fluid measurements, making it a versatile solution across numerous specifications.
This ensures a comprehensive approach to pipeline monitoring and fluid management.
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology

 

Technical Parameters
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Model TK1100 standard series TK1200 high accuracy series
Caliberl DN3-DN2200 DN10-DN300
Accuracy 0.5% 0.2%,0.3%
Installation method Hold,flange Hold,flange
Repeatability 0.1% 0.06%,0.1%
Measuring range 0-12m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 4.0MPa~0.25 Mpa
(classify by caliber)
4.0MPa~0.25 Mpa
(classify by caliber)
Lining material PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard,(scraper,it can be replaced by DN>350) Standard,(scraper,it can be replaced by DN>350)
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >2μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC) Integrated type≤90ºC,split type≤160ºC(rubber)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode Integrated,split Integrated,split
Output  signal 4-20mA current signal,frequency /pulse output 4-20mA current signal,frequency/pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis yes yes
Zero setting of empty pipe yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards JB/T 9248-1999 JB/T 9248-1999
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Model TK1300 hygienic series TK1500 battery powered series
Caliberl DN3-DN150 DN10-DN1200
Accuracy 0.2%,0.5% 0.5%
Installation method Thread,clamp Hold,flange
Repeatability 0.06%,0.1% 0.15%
Measuring range 0-12m/s(flow unit can be changed) 0-10m/s(flow unit can be changed)
Connecting flange   GB/T9119-2000 or any other choice
Pressure The highest 4.0MPa 4.0MPa~0.6 Mpa
(classify by caliber)
Lining material PFA(negative pressure resistance) PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard,(scraper,it can be replaced by DN>350)
Protection leve of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >2μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤160ºC Lntegrated type≤90ºC,split type≤160ºC(rubber,PO≤70ºC)
Ambient maximum temperature -30ºC~+65ºC -30ºC~+65ºC
Converter installation mode ntegrated,split Lntegrated,split
Output signal 4-20mA current signal,frequency/pulse output Frequency 0-5kHz
Power supply AC:85V~265V,DC:18V~36V 3.6V
Self diagnosis Yes Yes
Zero setting of empty pipe Yes Yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,GPRS
Explosion-proof No explosion proof/explosion proof  
Language Chinese,English Chinese,English
Product standards   JB/T 9248-1999
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Model TK1400 inserted type series TK1600 electromagneticheat meter series
Caliberl DN200-DN3000 DN15-DN1200
Accuracy 1.5%;2.5% 1.0%,2.0%,2.5%
Installation  method Flange,thread,on-line Hold,flange,thread
Repeatability 0.5% 0.3%;0.5%
Measuring range 0-10m/s(flow unit can be changed) 0-12m/s(flow unit can be changed)
Connecting flange GB/T9119-2000 or any other choice GB/T9119-2000 or any other choice
Pressure 1.6MPa 4.0MPa~0.6Mpa
(classify by caliber)
Lining material POM,PTFE,PFA PO,PTFE,PFA(negative pressure resistance),
rubber,polyurethane)
Electrode  material 316L,HC,HB,titanium,tantalum,platinum 316L,HC,HB,titanium,tantalum,platinum
Electrode form Standard Standard
Protection level of sensor IP65,IP67,IP68 IP65,IP67,IP68
Conductivity >5μS/cm(water>20μS/cm) >5μS/cm(water>20μS/cm)
Maximum temperature of medium Integrated type≤90ºC,split type≤130ºC(POM≤100ºC) Integrated type≤90ºC,Splitype≤160ºC(rubber,POM≤70ºC)
Ambient  maximum  temperature -30ºC~+65ºC -30ºC~+65ºC
Converter  installation  mode Integrated,split Integrated,split
Output signal 4-20mA  current  signal,frequency/pulse  output 4-20mA current signal,frequency /pulse output
Power supply AC:85V~265V,DC:18V~36V AC:85V~265V,DC:18V~36V
Self diagnosis Yes yes
Zero setting of empty pipe Yes yes
Communication RS485/Modbus,HART,PROFIBUS RS485/Modbus,HART,PROFIBUS
Explosion-proof No explosion proof/explosion proof No explosion proof/explosion proof
Language Chinese,English Chinese,English
Product standards   Refer to 9248-1999 JB/T
For an in-depth exploration of the comprehensive capabilities and specifications of our Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology, we invite you to reach out to us. Connect with our experts to acquire the detailed datasheet tailored to meet your specific needs.
Company Profile
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. represents the epitome of distinction within the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., Ltd. conglomerate.
In the vibrant metropolis of Shanghai, Cold Valley was established in 2013 as an esteemed member of Hanshan Intelligent Technology Co., Ltd., recognized for pioneering leadership in the industry.
Our founding team, drawn from elite international automation enterprises, collectively boasts over twenty years of rich experience in automation and engineering. With a decade-long expertise in consulting and digital solutions, we are passionately dedicated to offering unparalleled automation and digitization products and services from our strategic Shanghai base.
With an illustrious legacy spanning over two decades in the industry, we have unparalleled expertise in the petrochemical domain, with profound understanding of automation and digitalization requirements across various phases. Our forte lies in crafting customized products and solutions, seamlessly integrated with automation and digitalization, along with comprehensive life cycle services. We cater to a diverse array of industries, including petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology
Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology

Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai TechnologyAdvanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai TechnologyAdvanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai TechnologyAdvanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai TechnologyAdvanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology

Advanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai TechnologyAdvanced Non-Intrusive Electromagnetic Flowmeter with Highpeak Ai Technology

Frequently Asked Questions

How to Choose the Right Product?
A: Upon your inquiry, we promptly deliver an exhaustive technical document for your perusal, allowing you to meticulously assess key process parameters and technical specifics. Tailored to your unique requirements, we will precisely recommend the most appropriate model for your needs.

Desire a Confirmed Model?

A: Certainly. Once we receive your model specifications, we will diligently verify its compatibility, offering potential cost-effective enhancements if needed. After confirmation, we will advance with a comprehensive formal quotation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier