High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

Product Details
Customization: Available
Accuracy: 0.15%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (10)
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
  • High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
P200
Size
DN6-80
Sensor
Tube/Flange
Application
Environmental Protection
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measurement Object
Closed Pipeline
Certification
CE
Process Temperature
-100~180°c
Ambient Temperature
-40~60°c
Range
0.67~885nm3/H
Flange Standard
ANSI
Flange Material
316L
Flange Size
ANSI 2"150RF
Body Material
Aluminum
Element Material
316L
Mounting Style
Integral
Power Supper
24VDC
Output Signal
4-20mA
Output Indicator
Yes
Electrica Connect
1/2"NPT
Explosion Proof
Ex Ia Iict4
Pressure
0-50bar
Transport Package
Wooden
Trademark
Xi′an Dongfeng
Origin
China
HS Code
9026100000
Production Capacity
100000peices/Years

Product Description

P Series Precise Mass Flow & Density Meter
. Applied to Liquid, Gas, Slurry Mass Flow
. Mass Flow Accuracy ±0. 1%(Liquid),±0.5%(Gas) . Density Measuring Accuracy ±1kg/m3
. Normal Diameter DN10~DN250
. Process Temperature Ranges -40ºC~+350ºC
Component Parts of P Series Coriolis Mass Flow Meter
P Series Coriolis Mass Flow Meter is defined as P series Mass Flow Meter with flow accuracy is 0. 1%, whom is made ofP series mass flow Sensor and DPT100 Transmitter.

Features and Benefits of P Series Coriolis Mass Flow Meter
l Double U or double C type flow pipe design is better for measuring accuracy
l Provides integrated mass flow, volume flow, density, temperature measurement and the calculates Ensuring the utmost precision and efficiency, our solution addresses other relevant parameters seamlessly.meters
l Experience hassle-free and convenient on installation, there's simply no need for rectifiers, filters, or additional parts, and no special requirements for installing in a direct pipe section.
l Designed without moving parts and no requirement for frequent maintenance, ensuring highly stable functionalitywith no need for frequent calibration.
l Facilitates low range flow operations, minimizing pressure loss to maintainpeak efficiency throughout.
l Its compact build ensures that installation is cost-effective, saving on overall expenses.
l Fully compatible with N series A, allowing for variable (flanges faces intervaldistance) dimension setups.
l Delivers ultra-precise measurement capabilities combined with long-term stability for trustworthy custody transfer measurement.
l Boasts an ultra-wide turndown ratio ideal forgas measurement needs.
l The connected transmitter is designed for easy maintenance,being easily interchangeable, ensuring
l Operational integrity is not affected by changes in ambienttemperature.
Liquid Flow Rate Performance Index

 
    Mass flow rate Volume flow rate[1]
    Kg/h L/h
Maximum mass P10 1500 1500
flow rate P15 4500 4500
  P20 9450 9450
  P25 25500 25500
  P50 94500 94500
  P80 240000 240000
  P100 540000 540000
  P150 825000 825000
  P200 1650000 1650000
  P250 2700000 2700000

Mass flow accuracy[2]       15:1 within turndown[3] ±0. 1%
15:1 beyond turndown ±(zero stability/instant rate)×100%


Volume flow accuracy[2] FS ±0. 15±(Zero Stability / Instant Flow Rate) × 100%


 
Repeatability 15:1 within turndown ±0.05%
  15:1 beyond turndown ±1/2(Zero Stability / Instant Flow Rate)×100%

Kg/h
 
Zero Unwavering Stability

P10 P15 P20 P25 P50 P80 P100 P150 P200 P250

0.10 0.30 0.63 1.70 6.30 16.0 36.0 55.0 110.0 180.0

[1]The standard criterion of volume flow rate is as per the liquid's density. Concerning to the process liquid density isn't1000 kg/m3,the value of volume flow is equivalent to the value of maximum mass flow divided by liquid density calculation..
[2]Flow Accuracy includes repeatability, linearity and hysteresis.
[3]Turndown is defined as the value of maximum flow divided by minimum flow.

Accuracy, Turndown, and Pressure Loss of P50 teamed seamlessly with DPT100 Transmitter
Turndown (from the maximum flow) 20:1 15:1 5:1 1.5:1 1:1
Accuracy  ±% 0. 14 0. 1 0. 1 0. 1 0. 1
Pressure Drop MPa 0.001 0.002 0.02 0. 1 0.23

Note:when the maximum flow rate exceeds the established flowrate range, the acoustic noise from the pipeline may impact the precision.



Gas Measurement Performance
Mass flow accuracy (flow rate > zero stability/0.005) ±0.5%
(flow rate < zero stability/0.005) ±(zero stability/instant flow rate)x100% Mass flow repeatability (flow rate>zero stability/0.005) ±0.25%
(flow rate<zero stability/0.005) ±1/2(zero stability/instant flow rate)x100%

Standard Volume
In most application areas, customers are accustomed to utilizingstandard volume to evaluate the volume under pressure and temperature. Standard volume is also known as "standard mass" flow unitto the industry. fixed component liquid. Applicableto density measurements under standard conditions(receiving from reference data), flow meter would be output under the configuration of standard volume unit, which means that couldd be calculated between measured liquid quality and entrained liquid standarddensity, but no need the compensation of pressure, temperature and density. For more information, please contact your local agency. agency.


Pressure Loss
Pressure loss is affected by the sensor's geometric form, gas density and flow rate. While customers are suggested that the sensor pressureloss shouldn't exceed 0. 127Mpa when selecting design type. selection.


Flow Rate
The flow rate of gas measurement is significantly greater than the flow rate of liquid measurement; the higher flow rate leads to noise affecting the signal of flowmeter. meter. Therefore, the flow rate within sensor pipe should be lower 0.5 times than sounds rate when the pressure loss of flow meter under 0. 127Mpa.
 
High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

Model Selection Principle
l In the applied fields of Coriolis Mass Flow Meter, the Max. Flow rate is decided by pressure loss while the Min. Flow rate is decided by measuring accuracy
l Before selecting the product, the client or user should firstly refer to this manual, using the size selection software provided by Xi'an Dongfeng Machinery & Electronic Co., Ltd., as well as the user should provide the relevant data such as accuracy, flow rate, pressure loss, density, viscosity, temperature, etc., which ensures the correct size selection and application. The software can be obtained from salespersons of the agency or downloaded from the company

P50 Compact Installation
High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsNote:The Listed Flanges In The Below Tables Are Welding-neck Steel Pipe Flanges RF
 
Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D

F
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 922 201 18 125 165 180
65(Optional) 4.0 570 460 595 702 922 201 18 145 185 180
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D

F
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 922 201 18 127 165 180
65(Optional) 300 620 460 595 702 922 201 22 149.2 190 180



P50 Remote InstallationHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

Note:The Listed Flanges In The Below Tables Are Welding-neck Steel Pipe Flanges RF

Flange(GB/T 9115-2010)
A

B

L

C

H

E

M

I

D
Flange(HG/T 20592-2009)
DN(mm) PN(MPa)
50(Standard) 4.0 562 460 595 702 845 201 18 125 165
65(Optional) 4.0 570 460 595 702 845 201 18 145 185
Flange(HG/T 20615-2009)
A

B

L

C

H

E

M

I

D
Flange(ASME B16.5-2009)
DN(mm) PN(Class)
50(Standard) 300 606 460 595 702 845 201 18 127 165
65(Optional) 300 620 460 595 702 845 201 22 149.2 190

 

Company Profile
High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. stands as a distinguished pillar within the esteemed Hanshan (Cold Mountain) Intelligent Technology Co., epitomizing a commitment to unparalleled innovation and excellence.
(hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) officially embarked on its journey in the vibrant cityscape of Shanghai in 2013, heralding a transformative era of technological progress.
The founding team, a cadre of industry veterans from the world's foremost automation leaders, brings an extraordinary wealth of experience: over 20 years in the automation sector, in addition to two decades in automation engineering, and 10 years in pioneering digital solutions. Their mission is unequivocal: to deliver premier automation and digitization products and services to clients worldwide. Based strategically in Shanghai, China, the company is a shining icon of technological expertise.
Boasting an impressive legacy exceeding two decades in the petrochemical realm, the company holds unmatched insights into the automation and digitalization needs across the entire industry spectrum-upstream, midstream, and downstream. They offer a suite of professional-grade products and comprehensive solutions, meticulously crafted for industries such as petroleum, chemical, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals, guaranteeing excellence throughout the product lifecycle.
High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions
High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

High-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow SolutionsHigh-Precision Coriolis Mass Flow Meter for Reliable Industrial Flow Solutions

You may have these questions

How do I select the right product?
A: Upon receiving your inquiry, our extensive technical dossier will furnish all the essential insights you require. This documentation empowers you to thoroughly examine the process parameters and technical specifications pertinent to your needs. Armed with this information, we will expertly recommend the model that aligns impeccably with your precise requirements.

I would like a confirmed model. Can you provide that?
A: Absolutely. Once you express interest in a particular model, we will undertake a meticulous verification process to ensure its suitability. Should there be opportunities for cost-effective enhancements, we will readily propose optimization suggestions. Upon your confirmation, we will proceed to craft a formal quotation, meticulously tailored to meet your objectives.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now